PROBLEM
INDICATOR
No
water
Sensor flashes
c o m i n g
continuously
out of the
when user's
faucet
hands are
within the
sensor's range
Light in the
sensor does
not flash once
when user's
hands are
within the
sensor's range
Light in the
sensor flashes
once when
user's hands
are within the
sensor's range
Water flow
Sensor flashes
from spout
once when
does
not
user's hands
stop
are within the
sensor's range
Light in the
sensor does
not flash once
when user's
hands are
within the
.sensor's range
10
CAUSE
Low battery
Range is too short
Range is too long
Battery is completely used up
Sensor is picking up reflections from the
washbasin or another object
Connectors between the electronic unit and
solenoid are disconnected
Debris or scale in solenoid
The central orifice in the diaphragm is plugged
or the diaphragm is torn
The water supply pressure is higher than 8
bars
Debris or scale in diaphragm
**Sensor is dirty or covered
Sensor is picking up reflections from the
.washbasin or another object
SOLUTION
Replace battery
Increase the range
Decrease the range
The battery must be replaced
Eliminate cause of reflection
Connect the electronic unit
.connectors to the solenoid
Unscrew solenoid, pull out the
plunger and the spring from
the solenoid and clean them.
Use scale remover material if
needed. When replacing the
plunger, please make sure
that the spring is in vertical
position
Clean the orifice or replace
diaphragm
Reduce the supply water
pressure
Clean the orifice or replace
diaphragm
Clean or eliminate case of
interference
Decrease
the
range
eliminate cause of reflection
or

Publicidad