Operating manual
Regulations:
• This device complies with European directives.
• The declaration of conformity is available on our website.
• EAC (Eurasian Economic Community) conformity mark.
• This equipment conforms to UK standards.
The UK Declaration of Conformity is available on our website
(see front cover).
• This equipment conforms to Moroccan standards.
The C‫( م‬CMIM) Declaration of Conformity is available on our
website.
Disposal:
• This machine is subject to selective-collection regulations.
Do not dispose of this appliance in your domestic waste.
• The device must be disconnected from the mains supply
before removing the battery.

GENERAL DESCRIPTION

The ENERGY STATION FP is an autonomous starter (supplied without batteries) designed specifically for starting
vehicles fitted with a 12 - 24 V battery. This trolley can be used to set up one or two 12 V batteries (6 x 2 V cells) with a
capacity of up to 375 Ah each.
The appliance includes a 12 V / 30 A battery charger to charge the lead batteries present on the trolley (alternately) as
well as to charge an external battery. It also has a battery testing function.
To guarantee the correct functioning of the equipment and to preserve the life of the batteries on the trolley, it is imper-
ative to connect the ENERGY STATION FP to the mains supply after each use.
INTERNAL BATTERIES AND CHARGING CLAMPS
23 cm
45 cm

BATTERY TEST

or
• Unplug the power cable or set the ON/OFF switch to 'OFF'.
14
Translation of the original
instructions
Two 'internal' batteries (not included) must be fitted
before using the unit: 12 V, lead-acid batteries with
a capacity of 100 - 375 Ah each. Their size should
not exceed 45 x 53 x 23 cm and the total max.
weight is 100 kg.
To install them:
• Disconnect the power lead or set the ON/OFF
switch to the '0' position.
• Attach the four supplied battery terminals to the
four cables.
• Connect the batteries to the ENERGY STATION
FP ensuring correct polarity:
- the red cable to the positive (+) battery terminal
- the black cable to the negative (-) battery terminal
ENERGY STATION FP
12 V
12 V