ANOMALIES, CAUSES AND SOLUTIONS
Anomalies
The device beeps and the red LED
indicator light
Sparks emitted when
the clamps come into contact
with the battery.
The device can no longer start the
vehicle.
The LED
indicator lights
are flashing at the same time.
The two LED indicator lights
permanently on.
An indicator light
The indicator lights

WARRANTY CONDITIONS

The warranty covers any manufacturing defects or general faults for two years from the date of purchase (parts and
labour).
The warranty does not cover:
• Any transportation damage.
• The usual wear and tear of component parts (e.g. cables and clamps, etc.).
• Incidents due to improper use (power-supply errors, falls or dismantling, etc.).
• Environmentally related faults (pollution, rust or dust, etc.).
In the event of a breakdown, please return the appliance to your distributor enclosing:
- dated proof of purchase (receipt or invoice, etc.)
- a note explaining the breakdown
18
Translation of the original
instructions
The device has detected a polarity
turns on.
inversion.
Polarity OK. Battery too weak (<
11 V).
Non-insulated clamps have come
into contact with water.
The battery switch is in the 'ON'
position.
The voltage selector is in the wrong
position.
Switching the polarities.
Internal battery voltage is very low.
They may be damaged.
Fuse has burned out.
Internal battery (or batteries) is not
properly connected.
The battery (or batteries) is in reverse
polarity.
The battery (or batteries) is deeply
discharged (< 2 V).
Charger's thermal protection.
are
Charging time is too long.
is on.
The battery voltage is too high.
are flashing.
Causes
Check the batteries' polarity. Red clamp to the
positive (-) battery terminal and black clamp to
the negative (-) terminal.
Vehicle's battery is faulty and needs to be
replaced.
Check the clamps' condition and change them
if necessary. However, it is possible to start a
vehicle.
Set the battery switch to the 'OFF' position
before connecting the clamps to the battery.
Check that the vehicle's voltage corresponds
to the selected voltage.
Check the batteries' polarity.
Put the appliance back on charge in an at-
tempt to restore the batteries.
Check / replace the fuse.
Wire up the battery (or batteries).
Check polarity.
Internal battery (or batteries) is not working.
The charger has overheated because the am-
bient temperature is too high. It will automati-
cally resume charging when the temperature
has dropped sufficiently.
Internal battery is not working.
Check the wiring.