Being a 12 V charger, the ENERGY STATION FP alternately charges each battery individually for 30
minutes. Any manipulation of the batteries during the charging process is strongly discouraged (re-
placing batteries or readjusting the polarities if they have been inverted, etc.).
If carrying out an operation on one of the two batteries is absolutely necessary, disconnect the product
from the mains supply, carry out the operation and then reconnect it.
U
I
CHARGE
OK
1
Stage
: Analysis
Battery status analysis (charge level, reverse polarity or bad
battery connected, etc.).
2
Stage
: Recovery (10 A)
An algorithm for recovering damaged elements following a
deep discharge.
3
Stage
: Test
Sulphated battery test
Charging an external 12 V battery
It is possible to recharge an external battery. However, in order to charge it faster, it is recommended that the internal
batteries are fully charged beforehand.
Charging an external battery
12V
BATTERY 2
ON
Translation of the original
instructions
Lead load curve
1
2
Analysis
Recovery
Test
<1s
Max 8h
<1s
Connect the cables to the ENERGY STATION FP's 12 V outlet (red cable to the 12 V outlet,
black cable to the battery's negative [-] terminal).
Connect the external battery using the clamps, making sure that the polarity is correct.
Set the switch to the 'ON' position.
Connect the charger to the 230 V (50 - 60 Hz) mains system.
Set the switch to the 'ON' position.
Charging will start automatically.
During the charging process, the device will indicate the batteries' state of
progress.
3
4
Desulphation
Charging
Max 12h
Max 24h
4
Stage
: Desulphation (15.8 V)
Battery desulphation algorithm.
5
Stage
: Charging (30 A)
Rapid charging at the maximum current level to quickly reach
100% charged.
6
Stage
: Charge holding (13.6 V)
Maintaining the batteries at full charge.
ENERGY STATION FP
5
6
Charge
holding
No limit
.