12�3 Emptying The Condensate Container; Storage - goodbay 59513 Instrucciones De Uso

Acondicionador de aire local
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 82
12.3 Emptying the condensate container
WARNING!
The condensate is not of drinking water quality and can cause poisoning if consumed.
Do not drink the condensate!
NOTICE!
Water flowing out of the air conditioner can damage floors and furniture.
Empty the condensate container in a suitable place (e�g� over a drain)�
Make sure that the outlets for condensate are properly closed�
Condensate is produced in the operating modes cooling and dehumidification. A large part of the con-
densate is discharged to the outside via the exhaust air� The remaining condensate collects in a con-
tainer inside the unit. If the error code „E4" appears in the status display (c), the condensate container
must be emptied�
Proceed as follows to empty the condensate container:
1� Switch off the air conditioner and disconnect the mains cable from the socket at the plug�
2� Transport the air conditioner to a suitable place and take a collection container�
The collection container should be able to hold approx. 1.1 l.
3� Hold the collection container under the upper condensate outlet (8)�
4� Open the upper condensate outlet and allow the condensate to drain into the collection container�
5� Close the upper condensate outlet with the plug�
6� Empty the collection container�
7� Hold the collection container under the lower condensate outlet (10)�
7�1 Alternatively, you can position the air conditioner above a floor drain.
8� Open the lower condensate outlet and allow the condensate to drain into the collection container
or into a floor drain.
9� Close the lower condensate outlet with the plug�
The condensate container is now empy. The error code in the status display is no longer shown.
13

Storage

DANGER!
The air conditioner contains propane (R290) as a refrigerant. Propane in combination with air is highly
combustible and can lead to an explosion.
Only operate and store the air conditioner in rooms with an area of 10 m² to avoid the danger of a
concentration of flammable gas building up in the air.
Do not operate the air conditioner in rooms where there are sources of ignition (e.g. naked fla-
mes, electric heaters, gas appliances that are switched on)�
CAUTION!
Moisture in the air conditioner can lead to deposits and mould.
If you do not use the air conditioner for the next seven days, store it according to the following
instructions�
Perform the following operations before storing the air conditioner:
1� Empty the condensation tank (see chapter 12�4)�
2� Clean the air filter (see chapter 12.3).
3� Leave the air conditioner running in ventilation mode for 5 to 6 hours in a dry room to allow the in-
side of the air conditioner to dry�
4� Remove the batteries from the remote control�
5� Store the air conditioner in a suitable place� In particular, observe the instructions in the section
„Operation and storage conditions" in chapter 1.
Risk of poisoning!
Material damage!
Fire hazard!
Irritation of the respiratory tract!
EN
36

Publicidad

Tabla de contenido
loading