Sime MURELLE EQUIPE 100 BOX ErP Instrucciones Originales página 59

Ocultar thumbs Ver también para MURELLE EQUIPE 100 BOX ErP:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4.5.3
Pump high efficiency diagnose and remedy (fig. 22/a)
LED diagnose and remedy
Led color
Meaning
Continuous green
Normal.running
Red/green blinking
Abnormal.situation.
(pump.functional.
but.stopped)
Red blinking
Stopped.(e.g..pump.
blocked)
No LED
No.power.supply
Diagnostic
Cause
Pump.run.as.
Normal.operation
expected.or.is.faced.
to.a.phenomenon.
that.shortly.affects.
its.running
Pump.will.restart.
1..Undervoltage.or.
by.itself.after.the.
Overvoltage:.
abnormal.situation.
. U<160V.or.U>.253V
disappeared
2..Module.overvoltage:.
. T°.inside.motor.too.high
Reset.the.pump.
Pump.cannot.restart.
Check.LED.signal
itself.due.to.a.permanent.
failure
No.voltage.
1).Pump.is.not.connected.
on.electronics
to.power.supply
2).LED.is.damaged
3).Electronics.are.damaged
LED
Remedy
1..Check.voltage.supply:.
195V<U<253V
2..Check.water.&.ambient.
Change.pump
1). Check.cable.connection
2). Check.if.pump.is.runnning
3). Change.pump
ES
ENG
Fig..22/a
59

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Murelle equipe 150 box erpMurelle equipe 140 box erp

Tabla de contenido