–. "ALL 15" FAN ERROR (fig. 23/12)
riscaldamento 2
2
. The.fan.speed.does.not.fall.within.the.ra-
ted.speed.range..
. If. the. error. conditions. persists. for. two.
minutes,. the. boiler. activates. a. forced.
4
Circuito
stop.for.thirty.minutes..
riscaldamento 3
(impianto tre
. A.new.start.attempt.is.repeated.after.the.
zone)
2
Circuito
expiry.of.this.interval.of.time.
riscaldamento 2
Circuito
riscaldamento 3
2
(impianto tre
zone)
–. EXTERNAL PROBE ANOMALY
FLASHING" (fig. 23/13)
. When. the. external. probe. (SE). is. short-
circuited,.the.display.the.symbol.flashes.
Circuito
..
riscaldamento 2
. During.such.anomaly.he.boiler.continues.
normal.functioning.
Apre
Circuito
riscaldamento 3
(impianto tre
zone)
2
–. SAFETY THERMOSTAT INTERVENTION
Circuito
riscaldamento 2
FIRST MIXED ZONE "ALL 20" (fig. 23/14)
. When.it.results.that.the.ZONA.MIX.board.
is.connected.to.the.boiler.the.safety.ther-
mostat. intervention. switches. the. mixed.
Circuito
zone.plant.pump,.the.mix.zone.valve.clo-
2
riscaldamento 3
(impianto tre
ses.and.on.the.display.the.anomaly.ALL.
zone)
20..
. During.this.anomaly.the.boiler.continues.
to.function.normally..
Circuito
riscaldamento 2
Circuito
riscaldamento 3
(impianto tre
zone)
Apre
–. DELIVERY PROBE BREAKDOWN ANO-
MALY FIRST MIXED ZONE "ALL 21" (fig.
23/15)
. When.it.results.that.the.ZONA.MIX.board.
is.connected.to.the.boiler.and.the.delive-
2
ry.probe.is.open.or.short.circuited.on.the.
display.the.anomaly.ALL.21.appears..
. During.this.anomaly,.the.boiler.continues.
to.function.normally..
2
62
(impianto tre
1
zone)
2
Circuito
4
riscaldamento 2
Circuito
riscaldamento 3
(impianto tre
zone)
Fig..23/12
"
Fig..23/13
Circuito
riscaldamento 2
Circuito
riscaldamento 3
(impianto tre
zone)
Fig..23/14
Circuito
riscaldamento 2
Circuito
riscaldamento 3
(impianto tre
zone)
Fig..23/15
–. SAFETY THERMOSTAT INTERVENTION
SECOND MIXED ZONE "ALL 22" (fig.
23/16)
. When.it.results.that.the.ZONA.MIX.board.
is.connected.to.the.boiler.
. The.intervention.of.the.safety.thermostat.
switches.the.mixed.zone.plant.pump,.the.
mix.zone.valve.closes.and.on.the.display.
the.anomaly.ALL.22..During.this.anomaly.
the.boiler.continues.to.function.normally..
Fig..23/16
–. DELIVERY PROBE BREAKDOWN ANO-
MALY SECOND MIXED ZONE "ALL 23"
(fig. 23/17)
. When.it.results.that.the.ZONA.MIX.board.
is. connected. to. the. boiler. and. the. deli-
very. probe. is. open. or. short. circuited. on.
the.display.the.anomaly.ALL.23.appears..
During.this.anomaly.the.boiler.continues.
to.function.normally..
Fig..23/17
–. SOLAR COLLECTOR SENSOR ANOMALY
(S1) "ALL 24" (fig. 23/18)
.
When. the. solar. probe. is. open. or. short.
circuited,. on. the. display. the. anomaly.
ALL.24.appears..During.this.anomaly.the.
boiler.continues.to.function.normally.but.
loses.the.solar.function.that.is.no.longer.
available.
Fig..23/18
–. SOLAR PROBE ANOMALY STORAGE
TANK (S2) "ALL 25" (fig. 23/19)
.
When. the. solar. probe. is. open. or. short.
circuited,. on. the. display. the. anomaly.
ALL.25.appears..During.this.anomaly.the.
boiler.continues.to.function.normally.but.
loses.the.solar.function.that.is.no.longer.
available.
Fig..23/19
–. AUXILIARY
SENSOR ANOMALY
"ALL 26" (fig. 23/20)
.
When. the. solar. probe. is. open. or. short.
circuited,. on. the. display. the. anomaly.
ALL.26.appears..During.this.anomaly.the.
boiler.continues.to.function.normally.but.
loses.the.solar.function.that.is.no.longer.
available.
Fig..23/20
–. ANOMALY SOLAR APPLICATION COM-
PATIBILITY "ALL 27" (fig. 23/21)
.
When. the. hydraulic. configuration. is. not.
consistent.with.the.selection.solar.appli-
cation,.on.the.display.the.anomaly.ALL.27.
appears.. During. this. anomaly. the. boiler.
continues.to.function.normally.but.for.the.
board.is.active.in.the.solar.anomaly,.the.
function. is. only. available. antifreeze. col-
lector.
Fig..23/21
–. COMPATIBILITY INPUT (S3) ANOMALY
ONLY FOR SYSTEM 7 "ALL 28" (fig.
23/22)
. When. a. probe. is. connected. instead. of. a.
clean.contact.on.entry.S3.the.board.on.di-
splay.shows.the.anomaly.ALL.28..During.
this.anomaly.the.boiler.continues.to.fun-
ction.normally.but.for.the.board.is.active.
in.the.solar.anomaly,.the.function.is.only.
available.antifreeze.collector.
Fig..23/22
–. ANOMALY NUMBERS RELATED BOARD
"ALL 29" (fig. 23/23)
. When.one.of.the.board.ZONA.MIX/INSOL.
failure.or.does.not.communicate,.the.di-
splay.shows.anomaly.ALL.29..The.boiler.
functional. excluding. the. function. ZONE.
MIX/INSOL..
Fig..23/23
(S3)