6.6.2 View status information
Status information about the product is displayed in
the "Dashboard" menu, e.g.
n Current state
n Fault messages
n Charging processes
n IP address (parameter "Interfaces")
n ...
n Configuration settings made
n Load management
n Connection of an external energy meter
n ...
6.7
Setting the maximum charging current
The tasks described in this section may only
be carried out by a qualified electrician.
The maximum charging current is set to
16 A on delivery. This can be increased to
32 A if necessary.
u Navigate to the menu "Installation" > "General
Installation" and set the parameter "Installation
Current Limit [A]".
u Click the "Save" button to save the setting(s).
6.8
Integrating the product into a local
network
The tasks described in this section may only
be carried out by a qualified electrician.
Requirement(s):
ü The retrofit kit (USB-Ethernet adapter) for net-
working is installed.
1 Installation instructions for the retrofit kit.
u Connect the central router / switch and the
USB-Ethernet adapter with an Ethernet cable.
The product is configured as a DHCP client on de-
livery. After the product has been connected to the
router / switch, the IP address is assigned to the
product dynamically by the router.
If necessary, a static IP address can be assigned to
the product in the web interface.
u Navigate to the menu "Network" > "LAN" and
set the following parameters:
Parameter
Show LAN Configura-
tion
Mode for ethernet con-
figuration
Static network configur-
ation IP
Static network configur-
ation netmask
A detailed description of networking, the
connection to a backend system and load
management, including application ex-
amples, can be found on our website in the
download section for the selected product.
6.9
Setting operating modes
The tasks described in this section may only
be carried out by a qualified electrician.
6.9.1 "Standalone Autostart" operating mode
The product is operated as a stand-alone solution
without connection to a backend system. Charging
starts automatically as soon as the vehicle is
plugged in.
u Navigate to the menu "Backend" > "Connec-
tion" and set the following parameters:
Parameter
Connection Type
u Click the "Save" button to save the setting(s).
u Navigate to the menu "Authorization" > "Free
Charging" and set the following parameters:
Parameter
Free Charging
Free Charging Mode
Setting
u Select "Show".
u Select "Static".
u Enter static IP ad-
dress.
u Enter network
screen.
Setting
u Select "No Backend".
Setting
u Select "On".
u Select "No OCPP".
EN