Status
Two (2) LEDs show constantly green
One (1) LED shows constantly green
One (1) LED flashes green (charging cord not con-
nected).
No LEDs show.
The LED corresponding to the current state of
charge flashes green (while charging is in
progress).
One or more LEDs show constantly yellow.
One or more LEDs flash yellow.
One (1) LED quick-flashes red
3.5

Rotary switch

The rotary switch has the following three positions:
Transport
Standby / charging
operation
Operation
4

Technical data

Output voltage
Rated output power
Peak output power for max. 120 seconds
Energy available
Charging power
Protection class
12
English
Meaning
State of charge: 24 % to 12 %
State of charge: 12 % to 1 %
The Li-ion battery is completely discharged.
Charge the battery.
The portable energy system is switched off. Switch
it on.
If no LEDs light up after the system has been
switched on, consult Hilti Service.
The Li-ion battery is being charged.
A current spike occurred and the AC outputs were
deactivated.
Unplug all consumers. Turn the rotary switch to the
position for standby mode
and turn the rotary switch back to the position for
operational mode
ready for use.
If the message persists, consult Hilti Service.
The energy system is outside the permissible tem-
perature range. Operation or charging has been
interrupted.
Unplug the consumer or the charging cord from
the energy system and switch the energy system
to standby mode
ergy system back into the permissible temper-
ature range. As soon as the permissible range is
reached, the energy system can again be used or
charged.
If the message persists, consult Hilti Service.
A system fault has occurred. Disconnect the con-
sumer or the charging cord, switch the energy sys-
tem to transport mode
In transport mode all connections are inactive and the energy system
is switched off.
In standby mode the AC outputs are de-energized, the AC charging
input is active. The LEDs do not show.
In operational mode the AC outputs are active, a consumer can be
connected and operated. The LEDs indicate the state of charge or
fault messages.
High voltage
220 V ... 240 V / 50­60 Hz
3,600 W / 16 A
7,200 W / 32 A
2.1 kWh
1,000 W / 4 A
IP 54+
. Wait 10 seconds
. The energy system is again
. Then slowly bring the en-
and consult Hilti Service.