EXCLUSIVE
Reset function
In order to reset the boiler's operation in the event of a fault, it is necessary
to access the fault description screen. If the lockout is of a non-volatile type
that requires a reset procedure, this will be indicated on the screen, and
can be performed by pressing the "ok" button on the REC10.
At this point, if the correct operating conditions have been restored, the
boiler will restart automatically. There are a maximum of 3 consecutive
attempts at a release by the REC10, when used up it is possible to unlock
the boiler by cutting off and reconnecting the electrical supply.
LIMIT THERMOSTAT
LIMIT THERMOSTAT
RESET ATT. EXHAUSTED
REC10 ATTEMPTS EXHAUSTED
b
If the attempts to reset the boiler do not work, contact the Technical
Assistance Centre.
For fault E041
If the pressure drops below the safety pressured of 0.3 bar the boiler
displays the fault code "E041 - WATER TRANSDUCER PRESS OK FOR
AUTO FILL" for a transitional time of 10 min during which it is possible to
start the semi-automatic loading procedure, pressing the "ok" key to fill
the system (the procedure can only be started in HOT WATER ONLY or
HEATING AND HOT WATER).
WATER TRANSDUCER
PRESS OK FOR AUTO FILL
During the loading phase the scrolling message appears on the foot of the
page "SEMI-AUTOMATIC FILLING IN PROGRESS", the green and red
LEDs flash, while the pressure shown on the display should start to rise.
When the loading is finished the scrolling message "SEMI-AUTOMATIC
FILLING FINISHED" is displayed at the foot of the page and the green and
red LEDs come on fixed for about 4 seconds.
When the transitional time has finished, if the fault persists the fault code
E040 is displayed.
When the boiler has fault E040 manual loading should be carried out using
the filling tap (A), until the pressure is between 1 and 1.5 bar.
Then close the filling tap be sure to hear the mechanical click.
A
b
If the pressure drops frequently, contact the Technical Assistance
Centre.
For fault E060
The boiler is working normally, but does not provide any stability of the
domestic hot water temperature that, in any event, is supplied at a
temperature of around 50°C. The intervention of the Technical Assistance
Centre is necessary.
For fault E091
The boiler has an auto-diagnostic system which, based on the total number
of hours in certain operating conditions, can signal the need to clean the
primary exchanger (alarm code E091). Once the cleaning operation has
been completed, reset to zero the total hour meter with special kit supplied
as an accessory following procedure indicated below:
- access the technical parameters as explained in the section "4.1 Access
to the technical parameters"
- select EXHAUST PROBE RESET with the "up" and "down" keys,
confirming the selection
24
E020
E041
WEATHER COMPENSATION
THERMOREGULATION
COMBUSTION ANALYSIS
EXHAUST PROBE RESET
EXHAUST PROBE RESET
INSTALLER
INSTALLER
- select CONFIRM to confirm the rest of the flue gases probe meter or else
CANCEL to cancel the operation
THE PARAMETER WILL
THE PARAMETER
WILL BE CHANGED
CONFIRM
CONFIRM
CONFIRM OR DELETE SELECTION
CONFIRM OR DELETE
Nota: the meter resetting procedure should be carried out after each
in-depth cleaning of the primary exchanger or if this latter is replaced.
The total hours can be verified in the following way:
- select INFO on the initial screen of the REC10 and press "ok"
FRI
FRI
18/05/2013
MENU
MENU
INFO
INFO
HOT WATER TEMPERATURE
HOT WATER TEMPERATURE
- with the "up" and "down" keys select EXHAUST PROBE RESET to
display the value of the flue gases probe meter.
5.16 Error history
The ERROR HISTORY function is automatically enabled only after the
machine has been powered up for at least 2 consecutive hours, during this
period of time any alarms that arise would not be saved in the "error history".
The alarms can be displayed in chronological order, from the most recent
to the oldest, up to a maximum of 50 alarms; to display the alarm history:
- access the technical parameters as explained in the section "4.1 Access
to the technical parameters"
- select ERROR HISTORY with the "up" and "down" keys, confirming
the selection
RANGE RATED
CALIBRATION
COMBUSTION ANALYSIS
EXHAUST PROBE RESET
EXHAUST PROBE RESET
ERROR HISTORY
ALARM HISTORY
INSTALLER
INSTALLER
- scroll through the error history with the "up" and "down" keys; for each
alarms a sequential number is displayed, an error code and the date and
time the alarm occurred.
1 - 10:30 18/11/2013
FAN ANOMALY
USE ARROW KEYS TO SEE OTHER
TO SEE OTHER ANOMALIES
TECHNICAL
TECHNICAL
RANGE RATED
RANGE RATED
CALIBRATION
CALIBRATION
SWEEPER
BE CHANGED
CANCEL
CANCEL
SELECTION
PLANT
PLANT
12:17
1.3 bar
STATE
STATE
30
°C
.3
SET
SET
TECHNICAL
TECHNICAL
RANGE RATED
CALIBRATION
SWEEPER
E030
FAN ERROR
USE ARROW KEYS
ANOMALIES