Error History - Beretta EXCLUSIVE X Serie Manual Para El Instalador Y El Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61
List of combustion faults
ERROR CODE
ERROR MESSAGE
E021
ACC monitor error
E022
ACC monitor error
E023
ACC monitor error
E024
ACC monitor error
E067
ACC monitor error
E088
ACC monitor error
E097
ACC monitor error
E085
incomplete combustion
E094
incomplete combustion
E095
incomplete combustion
E058
mains voltage fault
E065
current modulation alarm
E086
flue gases obstruction alarm
4.15
INFO
The INFO function can be used to display a series of data regarding the system. The
passage from the display of one parameter to the next takes place by pressing the "up" and
"down" keys respectively.
b
Depending on the system configuration some of the info might not be available.
SCREED HEATER OPERATING HOURS
DELIVERY PROBE
RETURN PROBE
DOMESTIC HOT WATER PROBE
HIGH STORAGE TANK PROBE
LOW STORAGE TANK PROBE
SOLAR COLLECTOR
FLUE GAS PROBE
OUTDOOR TEMPERATURE SENSOR
EXT T FOR THERMOREG
FLOW METER / DHW SETPOINT OT+
FAN
DELIVERY ZONE 1
DELIVERY ZONE 2
FLUE GAS PROBE OPERATING HOURS
MAIN ZONE SET-POINT
ZONE 1 SET-POINT
ZONE 2 SET-POINT
4.16
Combustion info
The INFO function can be used to display a series of data regarding the system. The
passage from the display of one parameter to the next takes place by pressing the "up" and
"down" keys respectively.
INFO page 1
1
Number of calibrations at minimum power
(correct combustion test identified with code 18)
2
Number of calibrations at the speed of 3500 RPM
(correct combustion test identified with code 18)
3
Number of calibrations at default power RANGE RATED
(correct combustion test identified with code 18)
4
Number of calibrations at maximum boiler output
(correct combustion test identified with code 18)
5
Last calibration [1] PowMin - [2] 3500rpm - [4] Range Rated - [8] PowMax
6
Peak Iono of the last calibration
7
Reference value of PWM effort fan control
8
PWM fan control
9
Number of DataFlash AB writes
10
Number of DataFlash CD writes
INFO page 2.A
11.A
Iono curve correction at minimum power
(defined with correct combustion test 18)
12.A
Iono curve correction at the speed of 3500 RPM
(defined with correct combustion test 18)
13.A
Iono curve correction at default power RANGE RATED
(defined with correct combustion test 18)
14.A
Iono curve correction at maximum boiler output
(defined with correct combustion test 18)
15.A
Calibration test check performed [1] PowMin - [2] 3500rpm - [4] Range Rated - [8]
PowMax
16.A
Time counter [min] from last calibration to minimum power
17.A
Time counter [min] from last speed calibration of 3500 RPM
18.A
Time counter [min] from last calibration to default power RANGE RATED
19.A
Time counter [min] from last calibration to boiler maximum
20.A
Time counter [min] restart timing of calibration (maximum timeout to make the 4
calibrations)
These are temporary alarms that if they occur several times in an hour they become definitive; the alarm E097 is displayed and is followed by
These are temporary alarms that if they occur several times in an hour they become definitive; the last error to occur is displayed and is
followed by a post-purging of 2 minutes at the fan's maximum speed. It is not possible to release the alarm before the end of the post-purging
Temporary fault signalled during Pre-Purging. Post-Purging is maintained for 5 min at maximum fan speed.
SYSTEM PRESSURE
CURVE (combustion)
HEAT PUMP DELIVERY
HEAT PUMP RETURN
HEAT PUMP EXT. TEMP.
TREFR LOW PRESSURE PIPE
TREFR HIGH PRESSURE PIPE
TREFR CONDENSER
TREFR HEAT EXCHANGER
HEAT PUMP OPERATING MODE
HEAT PUMP FREQUENCY
HEAT PUMP COMPRESSOR TIME
HEAT PUMP CIRCULATOR TIME
HEAT PUMP FLOW SWITCH
HEAT PUMP OUTPUT
HEAT PUMP SET-POINT
NEXT ANTI-LEGIONELLA
DESCRIPTION OF TYPE OF ALARM
post-purging for 45 seconds at the fan's maximum speed.
It is always possible to release the alarm before the end of the post-purging.
unless the boiler's power supply is switched off.
These are temporary faults that restrict the ignition cycle.
INFO page 2.B (Identified with the value 12345 on line 11 - It changes status automatically
every 10 seconds)
11.B
12345
12.B
Iono Curve Auto-Correction Number at minimum power
(auto correction for alarm)
13.B
Iono Curve Auto-Correction Number at the speed of 3500 RPM
(auto correction for alarm)
14.B
Iono Curve Auto-Correction Number at default power RANGE RATED
(auto correction for alarm)
15.B
Iono Curve Auto-Correction Number at maximum output
(auto correction for alarm)
16.B
Maximum power calibration coefficient
17.B
Range Rated power calibration coefficient
18.B
Minimum power calibration coefficient
19.B
FIXCO2ALLPLUS value
20.B
DECCO2ALLPLUS value
INFO page 3 (Chronological order of the last 5 alarms/tests and related FAN speeds)
21
Identification code (17-18) of a test performed to verify correct combustion # 1
22
RPM/100 where alarm and/or test # 1 occurred
23
Alarm code and/or identification code (17-18) of a test performed to verify correct
combustion # 2
24
RPM/100 where alarm and/or test # 2 occurred
25
Alarm code and/or identification code (17-18) of a test performed to verify correct
combustion # 3
26
RPM/100 where alarm and/or test # 3 occurred
27
Alarm code and/or identification code (17-18) of a test performed to verify correct
combustion # 4
28
RPM/100 where alarm and/or test # 4 occurred
29
Alarm code and/or identification code (17-18) of a test performed to verify correct
combustion # 5
30
RPM/100 where alarm and/or test # 5 occurred
4.17

Error history

The ERROR HISTORY function is automatically enabled only after the machine has been
powered up for at least 2 consecutive hours, during this period of time any alarms that arise
would not be saved in the "error history". The alarms can be displayed in chronological
order, from the most recent to the oldest, up to a maximum of 50 alarms; to display the
error history:
- select TECHNICAL
INSTALLER
- for each alarms a sequential number is displayed, an error code and the date and time
the alarm occurred.
Note: Once enabled, the ERROR HISTORY function can no longer be disabled; there is no
procedure for resetting the error history.
If an alarm repeats consecutively, it is saved only once.
ERROR HISTORY
TECHNICAL
RANGE RATED
CALIBRATION
COMBUSTION ANALYSIS
EXHAUST PROBE RESET
ERROR HISTORY
1 - 10:30 18/11/2020
E030
FAN ERROR
USE ARROW KEYS TO SEE OTHER ANOMALIES
ENGLISH
EN
19

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Exclusive x 25r

Tabla de contenido