EN
USING YOUR DYSON APPLIANCE
PLEASE READ THE 'IMPORTANT SAFETY INSTRUCTIONS' IN THIS
DYSON OPERATING MANUAL BEFORE PROCEEDING.
ASSEMBLY
•
Lie the appliance on its back.
•
Attach the cleaner head by sliding it on to the connections on the lower front part
of the ball. Ensure the electrical plug on the cleaner head fits into the twin-block
connection on the body of the appliance, which is directly above the airway. Push
firmly: the cleaner head will click into place.
•
Stand the appliance up straight.
•
Attach the wand handle by sliding it on to the top of the appliance. The spring clip in
the handle will click into place.
•
Ensure the hose is straight. Press the red button on the hose. Slide the wand into the
hose.
•
Ensure the hose and wand sit in the recess of the handle. Slide the end of the wand
down into the handle to secure it.
•
Close the wand cap.
•
Slide the tool holder onto the side of the duct as shown.
•
Ensure the cyclone and clear bin unit is secured to the main body of the appliance.
•
Attach the tools as shown. In use, the tools can be attached to either the hose or the
wand.
•
Wind the cable anti-clockwise around the cable hooks. Secure with the clip.
OPERATION
•
Unwind the cable.
•
Plug the appliance into the mains electricity supply.
•
To switch 'ON' or 'OFF' press the power button, located as shown.
•
To use, recline the handle. The stabiliser stand will automatically lift up.
•
After use, return the appliance to the upright position, pushing it firmly into place.
The stabiliser wheels will automatically lower.
•
Then unplug the appliance, coil the cable safely and put the appliance away.
•
Switch 'OFF' the appliance, unplug and ensure it is upright before:
– changing or using tools
– removing the hose or airway inspection parts.
•
Use the cyclone carry handle to carry the appliance.
ATTACHMENTS
•
To release the wand, open the wand cap and pull the red tube up and away from the
handle until it clicks into place.
•
Should you wish to use the hose without the wand, follow the above instruction and
press the red button to release the wand from the hose.
CARPETS OR HARD FLOORS
•
The brush bar will always default to 'ON' (spinning) each time you switch the
appliance 'ON' and recline it for cleaning.
•
The brush bar will not rotate when the appliance is upright.
•
To switch the brush bar 'OFF' (e.g. for delicate rugs and hard floors):
– switch the appliance 'ON'
– recline the appliance
– press the brush bar 'ON/OFF' button – the brush bar will stop spinning.
•
The brush bar will automatically stop if it becomes obstructed. See 'Brush bar –
clearing obstructions'.
•
Before vacuuming your flooring, rugs and carpets, check the manufacturer's
recommended cleaning instructions.
•
Some carpets may fuzz if a rotating brush bar is used when vacuuming. If this
happens, we recommend vacuuming in 'hard floor' mode and consulting with the
flooring manufacturer.
•
The brush bar on the appliance may damage some carpet types. If you are unsure,
turn off the brush bar.
LOOKING AFTER YOUR DYSON APPLIANCE
•
Do not carry out any maintenance or repair work other than that shown in this Dyson
Operating Manual, or advised by the Dyson Helpline.
•
Only use parts recommended by Dyson. If you do not this could invalidate your
guarantee.
•
Store the appliance indoors. Do not use or store it below 0°C (32°F). Ensure the
appliance is at room temperature before operating.
•
Clean the appliance only with a dry cloth. Do not use any lubricants, cleaning agents,
polishes or air fresheners on any part of the appliance.
•
If used in a garage, always wipe the base plate, ball and stabiliser wheels with a
dry cloth after vacuuming to clean off any sand, dirt or pebbles that could damage
delicate floors.
VACUUMING
CAUTION:
•
Do not use without the clear bin and filters in place.
•
Fine dust such as plaster dust or flour should only be vacuumed in very small amounts.
•
Do not use the appliance to pick up sharp hard objects, small toys, pins, paper clips,
etc. They may damage the appliance.
•
When vacuuming, certain carpets may generate small static charges in the clear bin or
wand. These are harmless and are not associated with the mains electricity supply. To
minimise any effect from this, do not put your hand or insert any object into the clear
bin unless you have first emptied it and rinsed it out with cold water (see 'Cleaning the
clear bin').
•
Powerful suction can cause the hose to 'pull back' – please take care.
•
Do not work with the appliance above you on the stairs.
•
Do not put the appliance on chairs, tables, etc.
•
Before vacuuming highly polished floors, such as wood or lino, first check that the
underside of the floor tool and its brushes are free from foreign objects that could
cause marking.
•
Do not leave the cleaner head in one place on delicate floors.
EMPTYING THE CLEAR BIN
•
Empty as soon as the dirt reaches the level of the MAX mark – do not overfill.
•
Switch 'OFF' and unplug before emptying the clear bin.
•
To remove the cyclone and clear bin unit, press down on the red button at the rear of
the carrying handle on the cyclone.
•
To release the dirt, press all the way down on the red button at the rear of the carrying
handle on the cyclone.
•
To minimise dust/allergen contact when emptying, encase the clear bin tightly in a
plastic bag and empty.
•
Remove the clear bin carefully.
•
Seal the bag tightly, dispose as normal.
•
To refit:
– close the clear bin base so it clicks into place
– push the cyclone and clear bin unit into the main body of the appliance; it will click
into place
– ensure the cyclone and clear bin unit is secure.
CLEANING THE CLEAR BIN
•
Remove cyclone and clear bin (instructions above).
•
To separate the cyclone unit from the clear bin press the red button to open the clear
bin base. This exposes a small silver button behind the red opening mechanism. Press
the silver button and separate the cyclone unit from the clear bin.
32
•
Clean the clear bin with cold water only.
•
Ensure the clear bin is completely dry before replacing.
•
Do not use detergents, polishes or air fresheners to clean the clear bin.
•
Do not put clear bin in a dishwasher.
•
Do not immerse the whole cyclone in water or pour water into it.
•
Clean the cyclone shroud with a cloth or dry brush to remove lint and dust.
•
To refit:
– fit the cyclone shroud into the clear bin so that the silver button clicks and engages
– close the clear bin base so it clicks into place
– push the cyclone and clear bin unit into the main body of the appliance;
it will click into place
– ensure the cyclone and clear bin unit are secure.
WASHING YOUR FILTERS
•
Your appliance has two washable filters, located as shown.
•
Check and wash the filters regularly according to instructions to maintain
performance.
•
Switch 'OFF' and unplug before checking or removing the filters.
•
The filters may require more frequent washing if vacuuming fine dust.
•
Wash the filters with cold water only. Do not use detergents.
•
Do not put the filters in a dishwasher, washing machine, tumble dryer, oven,
microwave or near a naked flame.
•
To remove filter A see the 'Wash filters' section in this Dyson Operating Manual.
•
After washing lay filter A on its side and leave at least 24 hours to dry completely
before refitting.
•
To remove filter B:
– turn the central locking dial on the outer cover of the ball anti-clockwise until the
cover is released
– lift off the cover
– turn the filter one-quarter anti-clockwise to release.
•
Filter B should be rinsed and tapped out until the water runs clean, then tapped out
again to ensure all excess water is removed. Leave to dry completely for 24 hours.
•
It is normal for the filter in the ball to turn grey in colour.
•
To refit filter B:
– refit the filter on to the ball
– secure the filter by turning it one-quarter turn clockwise.
•
When refitting the outer cover of the ball, keep turning the central locking dial
clockwise. When it starts to click it is locked.
LOOKING FOR BLOCKAGES
•
Switch 'OFF' and unplug before looking for blockages. Failure to do so could result in
personal injury.
•
Look for blockages in the wand, airways and cleaner head.
•
To remove the base plate to access an obstruction, see 'Base plate – disassembly/
reassembly'.
•
To look for blockages in the airway between the ball and the cleaner head you will
need to remove the cleaner head: see 'Base plate – disassembly/reassembly' below on
how to do this.
•
Beware of sharp objects when checking for blockages.
•
Refit all parts securely before using.
•
Clearing blockages is not covered by your guarantee.
CLEARING BLOCKAGES – THERMAL CUT-OUT
•
This appliance is fitted with an automatically resetting thermal cut-out.
•
Large items may block the tools or wand inlet. If any part becomes blocked the
appliance may overheat and automatically cut-out.
•
Switch 'OFF' and unplug. Leave to cool down for 1-2 hours before checking filter or for
blockages. Do not operate the wand release catch.
•
Clear any blockage before restarting.
•
Clearing blockages is not covered by your guarantee.
BRUSH BAR – CLEARING OBSTRUCTIONS
•
If your brush bar is obstructed, it may shut off. If this happens, you will need to remove
the blockage.
•
Switch 'OFF' and unplug before proceeding. Failure to do so could result in personal
injury.
•
Beware of sharp objects when clearing obstructions.
•
If you still cannot clear the obstruction, please follow the instructions below to remove
the base plate. This gives more access to the obstruction. Alternatively, contact a Dyson
expert on the Dyson Helpline or visit the website. Clearing brush bar obstructions is
not covered by your guarantee.
BASE PLATE – DISASSEMBLY/REASSEMBLY
•
Switch 'OFF' and unplug before proceeding. Failure to do so could result in personal
injury.
•
Lie the appliance on its front.
•
Detach the red 'C' clip which is on the connection between the cleaner head and the
appliance. It is quite firm, but do not pull it off roughly. Use a constant, firm pressure.
•
Pull the cleaner head away from the appliance. Use a constant, firm pressure.
•
At each end of the cleaner head are two levers:
– swing them out at right angles
– the base plate will disengage
– lift up the top edge, so it rotates to the upright position
– lift out.
•
Beware of sharp objects when clearing obstructions.
•
To refit the base plate:
– fit the 3 lugs on the lower edge of the base plate into the 3 slots in the base of the
cleaner head
– swing the upper edge of the base plate down; it will click into place.
•
To secure the base plate push both levers back into position so they are flush with the
surface of the cleaner head.
•
Refit the red 'C 'clip onto the cleaner head. The flatter edge of the clip fits against the
cleaner head. It is easier to slide one lug into its slot before the other.
•
Lie the appliance on its back.
•
Attach the cleaner head by sliding it on to the connections on the lower front part
of the ball. Ensure the electrical plug on the cleaner head fits into the twin-block
connection on the body of the appliance, which is directly above the airway. Push
firmly: the cleaner head will click into place.
BRUSH BAR – TROUBLESHOOTING
•
If the brush bar has stopped spinning, follow the instructions above on clearing
obstructions. Alternatively, contact a Dyson expert on the Dyson Helpline or visit the
website.
DISPOSAL INFORMATION
Dyson products are made from high grade recyclable materials. Please dispose of this
product responsibly and recycle where possible.