Kohler Anthem K-28209-NA Instrucciones De Instalación página 16

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Clean the Debris Filters
CAUTION: Risk of personal injury. The valve may contain hot water. Be careful when draining any residual water.
Turn OFF the water supply to both inlets.
Start the shower for a few seconds to release trapped pressure and ensure that you have isolated the water supply.
Disconnect the power.
Unthread the screw to remove the cover.
Lift and remove the retention clips.
Remove the connectors. The O-ring and screen may be attached to the end of the connector.
If the screen remains in the connector, use a pair of needlenose pliers to remove the debris filter from the connector.
Clean the debris filters to remove any dirt or debris.
NOTE: The check valve is located within the product and does not require routine servicing. If the check valve needs to
be replaced, use a blunt object to pull the check valve from the product and replace.
Reassemble the inlet connections.
Replace the cover. Secure with the provided screw.
1430527-2-A
Retention Clips
Debris Filters
Connectors
16
Kohler Co.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Anthem k-28209

Tabla de contenido