Parameter
Inner fireplace room safety distances
(sides)
Outer fireplace safety distances
(back)
Outer fireplace safety distances
(sides)
Outer fireplace safety distances
(frontal)
Fireplace room ventilation
(entry - exit)
Minimum safety distance to hot air outlets
(mm)
Average temperature of smoke
Type of combustion
Flue liner
Fuel
Humidity fuel logs
Certification year
Certificate number
1.2 Breakdown of delivery components
(
Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1. Fireplace's body.
2. Heat-resistant spray paint for touch-ups.
3. Sliding door opening adjustment pieces.
4. Bag with 32x screws (G 500, G 500 +Plus 250) | Bag with 24x screws (G 300, G 300 +Plus 180, G 350, G 350 +Plus 200,
G 425, G 425 +Plus 180, G 450, G 450 +Plus 200 and G 505)
5. Cleaning cloth
6. Heat-resistant glove.
7. Tool for handling registers and opening door.
8. Leveling and adjustable foots.
9. External air intake kit. (External air inlet connector ᴓ120 mm, connector support, air inlet cover and screws).
10. 8x Hot air outlet connector of ᴓ120 mm (G 500, G 500 +Plus 250) | 6x Hot air outlet connector of ᴓ120 mm (G 300, G
300 +Plus 180, G 350, G 350 +Plus 200, G 425, G 425 +Plus 180,G 450, G 450 +Plus 200 and G 505)
11. Documentation bag: output declaration, energy label, guarantee, technical sheet, and installation and operating
characteristics manual.
12. Optional: +Plus 250 (G 500 +Plus 250) | +Plus 200 (G 350 +Plus 200, G 450 +Plus 200) | +Plus 180 (G 425 +Plus 180, G
300 +Plus 180)
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I. ATTENTION: The measurements admit a tolerance of 0.3%.

2. REQUIREMENTS PRIOR TO INSTALLATION

ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH
UPON INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground. Make sure the ground where the appliance will be placed is able to support the weight of the device. If not, you will need
a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
2.2 Flue liner. It is mandatory to have a smoke-tight Flue liner going from the connecting point of the base to the outside in observation
of the smoke pipe diameter. The good condition and suitability of this smoke pipe must be certified by a professional and
must also observe the relevant national regulations. This Flue liner should not be shared with other devices (see Table 1.1
Technical specifications). In cases of too much draught, when the duct exceeds 7 meters in length, or the measurement exceeds 20
Pa, the draft must be adjusted. To do this, use the second part of the baffle plate.
2.3 Type of appliance. Fireplace with vermiculite plates in the bottom, sides and baffle plate, grill embers and ash tray. The device
is ready to install. The entire interior and the door assembly can be removed if necessary, to make it easier to transport and install.
2.4. Insulating procedures.
2.4.1. Apparatus insulation. The fireplace must be insulated with insulation panels (Type A-1, EN13501-1) on its sides, back and
upper part.
2.4.2 Fireplace room insulation. It is also convenient to use insulation panels on the inner walls of the fireplace (Type A-1, EN13501-
1).
2.5. Safety distances. Base must be insulated for model G 505. You must be respected the values described in 1.1 Technical
characteristics
2.5.1. Inner fireplace room safety distances. You must be respected the values described in 1.1 Technical characteristics.
2.5.2. Outer fireplace safety distances. Anything fragile or flammable (textile, electronics, wood, paper wall, glass, chalk...) should
be separated of the appliance and respected the safety distances described in 1.1 Technical characteristics.
We must take special care in those fireplaces with wooden shelves or similar: we must prevent and avoid the possibility of hot air that
expels the device falls directly on the wood, in these cases, flammable items should be properly insulated.
2.6 Fireplace room. Fireplace room must be built with non-combustible materials and should not rest on the apparatus and the points
of contact (such as the front frame see picture B.2 of the ANNEXED DOCUMENT). Inside should not contain flammable or fragile
materials such as wood, wallpaper, glass, chalk paper, etc.).
2.7. Ventilation. It is imperative that the niche where the appliance is installed ventilation available.
G 300
+Plus 180
(mm)
(mm)
(mm)
(mm)
2
(cm
)
(ºC)
182,9
Model
G 350
G 425
+Plus 200
+Plus 180
20
150
150
1000
450
250
189,9
189,9
INTERMITENT
NOT SHARED
NATURAL WOOD
12-20 % - two years under cover
2019
1880-CPR-029-19 | 1880-CPR-062-19
G 450
G 500
+Plus 200
+Plus 250
189,9
189,9
11