Before Installation; Information To Be Transmitted To The Pole Support After Sales Service If Any - ROBLIN INFINITY Modo De Empleo

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
UK ELECTRICAL CONNECTION - ELECTRICAL REQUIREMENTS
Any permanent electrical installation must comply with the lastet I.E.E Regulations and local Electricity Board regu-
lations. For your own safety this should be undertaken by a qualified electrician e.g. your local Electricity Board, or a
contactor who is on the roll of the National Inspection Council for Electrical Installation Contracting (NICEIC).
Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating inside
the cooker hood.
FUSE
ON
FUSE
FUSE
ON
ON
This appliance is fitted with a 2 core mains cable and must be permanently connected to the electricity supply
via a double-pole switch having 3mm minimum contact gap on each pole. A switched Fuse Connection Unit to BS.1363
Part 4, fitted with a 3 Amp fuse, is a recommended mains supply connection accessory to ensure compliance with the
Safety Requirements applicable to fixed wiring instructions.
BLUE (NEUTRAL)
BROWN (LIVE)
The wires in this mains lead are coloured in accordance with the following code :
Green & yellow :
Blue :
L
Brown :
L supply
N
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying
DP
N Supply
the terminals in your connection unit, proceed as follows :
The wire which is coloured blue must be connected to the terminal which is marked with the letter 'N' or coloured black.
The wire which is coloured brown must be connected to the terminal which is marked with the letter 'L' or coloured red.
GREEN & YELLOW
(EARTH)
Display the nameplate attached on the body of the hood, inside, behind the filters. The information indicated by this label
are required for service support center for technical assistance support.
1
Reporter and keep following the marked references
INFORMATION TO BE TRANSMITTED TO THE POLE SUPPORT AFTER
1
2
3
Earth
Live

BEFORE INSTALLATION

P o l e S . A . V s u p p o r t : 0 4 . 8 8 . 7 8 . 5 9 . 9 3
SALES SERVICE IF ANY
CODE PRODUIT :
CODE FUN :
N° DE SERIE :
Neutral
WARNING
WARNING
3
2
1 2 3
GB

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Futura

Tabla de contenido