[d] Air Filter
Plastic mesh air filters remove dirt or dust from the air, and keep the condenser from getting clogged. If the filters get clogged,
the icemaker's performance will be reduced. Remove and clean the air filter(s) at least twice per month:
1) Remove the air filter.
Note: Do not put your hand inside the machine compartment.
2) Clean the air filter by using a vacuum cleaner. When severely clogged, use warm water and a neutral cleaner to wash the air
filter.
3) Rinse and dry the air filter thoroughly.
After cleaning, be sure to place the air filter back in position.
[e] Icemaking Water System
Water Cleaning
Clean the water circuit with fresh water either automatically or manually.
Automatic water cleaning: Set the user setting "U.44" to a desired frequency (see "II. 2. USER SETTINGS").
Manual water cleaning:
The icemaker automatically resumes icemaking operation after cleaning the water circuit.
Automated Chemical Cleaning
Effectively clean the water circuit by manually feeding a chemical.
Wear protective equipment (e.g. protective glasses) when using the citric acid or sodium hypochlorite solution. The solution may
spout out and splash into your eyes. In that case, wash your eyes with clean water.
If the citric acid solution is found dripping on the sheet metal parts, wipe it off thoroughly to prevent rust.
1) Make either of the following solutions to fit the intended purpose.
Cleaning (descaling):
Sanitising:
2) Open the door, and remove all ice from the storage bin. Check that the
separator is attached in its correct position as shown. Otherwise, the
solution may splash onto the ice in the storage bin.
3) Press and hold the cleaning button for 3 seconds. The display flashes
the current mode. For example, the display showing "run" during the
icemaking operation starts to flash "run".
4) When the display changes to "cln", pour the following amount of solution
into the water tank carefully not to overflow it.
KM-40C-HC: 2.0 litres
KM-60C-HC: 2.5 litres
KM-80C-HC: 3.0 litres
5) Rinse the bin liner with clean water to remove any solution spilled in the storage bin. Then, close the door.
6) Press the cleaning button (or wait for 15 minutes) to start the automated chemical cleaning.
7) The unit resumes the original state when the cleaning is over.
If the ice made after the automated chemical cleaning tastes wrong, immediately stop using the icemaker and call for service.
Press the cleaning button while the display does not show "oFF".
3 litres of 2% citric acid solution
3 litres of water mixed with 11 ml of 5.25% sodium hypochlorite solution
NOTICE
CAUTION
NOTICE
Separator
Water Tank
WARNING