8. Operation and maintenance

Only waste water from hand washbasins, showers and washing machines may be fed into the system (so-
called grey water).
The Securix filter should be checked regularly for blockages and cleaned if necessary.
8.1
Cleaning the Securix filter
Float valve
To clean the Securix filter, remove the filter
unit including the float valve.
8. Operation and maintenance
Under no circumstances should waste water containing solids or faecal
matter be discharged into the system.
The
This is done by turning the filter unit approx. 30° in an
anti-clockwise direction.
Seal
The filter can be cleaned under running water with a
brush. If necessary, a neutral detergent can be used.
Filter element
www.graf.info
26 / 52
Position
for removal
filter
unit
must
be
To reinsert the filter unit, lubricate
the seal with lubricant (alternatively
washing-up liquid).