5.4 SET ALARM

In weighing mode or counting mode, long press
'HL---ZL' and 'HL---PCS'. 'HL---ZL' stands for set weight alarm, while 'HL---PCS' stands for set quantity alarm, press
confirm.
The 'WEIGHT' window display the last setted alarm upper limit and the '-HH-' indicator turns on, if you do not need to change the previous
set value, press
key to directly enter the next step to set the alarm of the lower limit; if you need to change the previous set value, press
key to input the number, press
then automatically enter the next step to set the alarm lower limit.
If you just enter the state of setting alarm lower limit, the 'WEIGHT' window displays the last setted weight lower limit and prompt '-LL-' in
turn. The operation of this process is the same as setting alarm upper limit. After the setting of alarm lower limit, enter the setting of alarm
mode.
When setting the alarm mode, the 'WEIGHT' window displays '-IN-' stands for set alarm within OK range, '-OUT-' stands for set alarm
outside of the OK range, and '-NO-' stands for no alarm. At this time, press
During the setting alarm process, press

5.5 WEIGHT CALIBRATION

After starting up the scales, long press
The 'WEIGHT' window displays 'D-----2', press
The 'WEIGHT' window displays 'DOT--1', press
confirm.
The 'WEIGHT' window displays 'ZERO0.5', press
press
key to confirm.
The 'WEIGHT' window displays 'FULL' and the maximum capacity of the scale, press
the maximum range of 150kg scales would be '150.000', and press
The 'WEIGHT' window displays '-LOAD-' and the weight of the last calibration, press
20kg this time, input '020.000', and press
after stabilization, and the calibration is completed.
During the weight calibration process, press
Chers utilisateurs,
key. The 'WEIGHT' window displays 'HL---ZL. Press
key to confirm current value, and began to set the next, if it is the most at the end of the value,
key to exit the setting, and the current setting value is invalid.
key to enter the calibration.
key to adjust the division value within '1/2/5/10/20', and press
key to adjust the number of decimal points within'0/1/2/3/4', and press
key to adjust the range of zero within'0.5/1.0/1.5/2.0/2.5/3.0/3.5/4.0/4.5/5.0', and
key to confirm. Put the corresponding weight on the scale plate, press
key to exit.
key to switch and press
key to adjust the maximum range, for example,
key to confirm.
key to input the weight, for example, if you load
BOW-P USER MANUAL
key to switch between
key to
key to confirm.
key to confirm.
key to
key to confirm