Dtect200C_2610067510_06-21.qxp_D-tect200 6/14/21 9:30 AM Page 13
Universal detector
USB-C cable
Article number
Rated voltage
Capacity
Weight (with rechargeable battery)
Dimensions (length × width × height)
Protection rating
E)
Recommended ambient temperature during charging
Permitted ambient temperature during operation
Permitted ambient temperature during storage
A) Depends on material and size of the objects, as well as material and condition of the substrate and the selected view. The best
results can be obtained in homogeneous, dry substrates. In addition, a deviation in the indicated object depth of ±0.5 mm/cm for
objects deeper than 2.36 inches (60 mm) must be taken into account.
B) Depends on the material and condition of the substrate
C) Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.
D) Depends on battery in use
E) The lithium-ion battery is not covered by IP 5X.
The serial number (20) on the type plate is used to clearly identify your detection tool.
Tool Power Supply
The tool can be operated with a Bosch
rechargeable lithium-ion battery pack.
Use only Bosch rechargeable
lithium-ion
listed in the technical data section of this
manual. Use of other battery packs may increase
the risk of fire, personal injury and property
damage.
Note: The battery pack is supplied partially
charged. To ensure full capacity of the battery
pack, completely charge the battery pack in the
battery charger before using for the first time.
Use only Bosch chargers
listed in the technical data
section of this manual. Use of other chargers
may increase the risk of fire, personal injury and
property damage.
The lithium-ion battery pack can be charged at
any time without reducing its service life.
Technical Data
Preparation
Interrupting the charging procedure does not
damage the battery pack.
The "Electronic Cell Protection (ECP)" protects
the lithium-ion battery pack against deep
discharging.
battery
packs
discharged, the tool is switched off by a
protective circuit.
• Do not switch the tool back on after it has
been switched off by the protective circuit.
The battery pack can be damaged.
To insert the charged battery pack (10), align
battery pack and slide it into the battery port
until it locks into position. Don't force.
To remove the battery pack (10), press the
battery release tabs (9) and pull the battery pack
out of the battery port (23). Do not use force to
do this.
• Remove the batteries from the tool when not
using it for extended periods. When storing
for extended periods, the batteries can
corrode and self-discharge.
-13-
1.5 lbs (0,69−0,70 kg)
9.1 x 4.17 x 4.4 in (231 × 106 × 112 mm)
32 to +95 F (0 °C to +35 °C)
14 to +95 F (–10 °C to +50 °C)
-20 to +158 F (–20 °C to +70 °C)
When
the
battery
D-tect 200 C
1600A024N2
5 V
2A max
D)
IP 5X
pack
is