Switching On/Off - Bosch D-tect200C Instrucciones De Funcionamiento Y Seguridad

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Dtect200C_2610067510_06-21.qxp_D-tect200 6/14/21 9:30 AM Page 14
Inserting/changing the button cell
(see figure C)
To be able to save the time on the detection tool,
a button cell (27) must be used.
Unscrew the screw (25) on the button cell
holder (24). Pull the button cell holder out of the
button cell port (26) with an auxiliary tool (e.g.
a flat-head screwdriver).
Remove the empty button cell (27) and insert a
new button cell. Ensure that the polarity is
correct according to the illustration on the
button cell holder (the positive terminal of the
button cell must be facing upwards).
With the button cell fitted, slide the button cell
holder (24) into the port (26). Ensure that the
button cell holder is inserted correctly and fully,
Protect the detection tool against moisture and
direct sun light.
Do not expose the detection tool to any
extreme
temperatures
temperature. In case of large variations in
temperature, leave the detection tool to adjust
to the ambient temperature before switching it
on. The accuracy of the detection tool and the
functionality of the display may be compromised
if exposed to extreme temperatures or variations
in temperature.
Hold the detection tool only at the intended
grip area (11), so as not to influence the
measurement.
Use or operation of transmitting systems, such
as WLAN, UMTS, radar, transmitter masts or
microwaves, in the close proximity can
influence the measuring function.
The measuring values can be impaired through
certain ambient conditions. These include, e.g.
the proximity of devices that produce strong
electric, magnetic or electromagnetic fields,
moisture, metallic building materials, foil-
laminated insulation materials or conductive
wallpaper or tiles. Therefore, also observe other
information sources (e.g. construction plans)
before drilling, sawing or routing into walls,
ceilings or floors.
Preparation
as otherwise protection from dust and splashes
is no longer guaranteed.
Retighten the screw (25) on the button cell
holder (24).
away from children. This product contains a
lithium button/coin cell battery. If a new or used
lithium button/coin cell battery is swallowed or
enters the body, it can cause severe internal
burns and can lead to death in as little as 2
hours. Always completely secure the battery
compartment. If the battery compartment does
not close securely, stop using the product,
remove the batteries, and keep it away from
children. If you think batteries might have been
swallowed or placed inside any part of the body,
seek immediate medical attention.
Operating Instructions
Do not wear gloves when taking measurements
and make sure that you are properly earthed. If
you are not properly earthed, the classification
of the object (live wire) may be impaired.
or
variations
in

Switching on/off

To switch on the detection tool, press either the
on/off button (8) or the red start button (16).
To switch off the detection tool, press the on/off
button (8) again.
If no button on the detection tool is pressed for
approx. 5 minutes and the detection tool is not
moved, the detection tool will automatically
switch itself off to preserve battery life. You can
change the switch-off time in the main menu
(see "Main Menu", page 20).
-14-
Chemical Burn Hazard. Keep
lithium button/coin batteries
Before switching on the detection tool,
ensure that the sensor area (19) is dry. If
necessary, use a cloth to dry the detection
tool.
If the detection tool has been exposed to a
significant change in temperature, leave it to
adjust to the ambient temperature before
switching it on.