Temperature unit option
Access this setup menu to select the temperature unit to use:
°C – default option-
•
°F
•
Select Language
Access this setup menu to select the language in use on the device:
English –default language-
•
•
Italiano
•
Deutsch
Portugues
•
Auto Off
Access this setup menu to activate or deactivate the auto-shutdown of the instrument:
YES: The instrument automatically turns off after 20 minutes of inactivity.
•
NO: The instrument remains always on, even if you are not using it.
•
Note: Auto-switch-off of the instrument is disabled, if data is being recorded with the automatic Data Logger
mode
.
IMPORTANT: The correct and systematic use of options Backlight Mode, Brightness, Sleep Mode ed Auto Off
allows to significantly lengthen battery life.
Restore Factory Default
Access this setup menu to restore the instrument to factory conditions.
IMPORTANT: Restoring the factory parameters does not delete the stored data.
Software DataLink+
It is possible to connect the instruments of the ReVio series to the PC and then use the DataLink + 1.9
software (and later versions) to perform data download, Data Logger directly on PC and exports in .xls (Excel)
and .pdf. The software can be downloaded for free from the web site (pay attention to the correct
installation of the drivers).
•
https://www.giorgiobormac.com/it/download-software_Download.htm.
•
Connect the USB cable inside each package to the USB port on the top panel of the instrument and the
other end to a COM port on the computer.
•
Use the USB cable supplied with the instrument only.
Start the program and then switch on the instrument.
•
•
Wait for connection to be established (the connection data are shown at the bottom left of the display).
• Functions
•
Download: the data saved in the instrumental memory are downloaded to a PC and displayed in the
table for processing.
M+: instantaneous acquisition of a value (equivalent to the manual Data Logger option).
•
•
Logger: automatic acquisition with set frequency.
Empty: emptying the data in the table. If the password is active, it will be requested.
•
Export to Excel / Export to PDF: export to PDF and Excel of all the data in the table, of graphs,
•
calibration reports and instrumental information.
Save to file / Open from file: saving the data in the table and possibility to reload them in order to
•
process them or continue recording.
Select the language: set the interface language (Eng – Ita – Deu – Esp – Fra – Cze).
•
Table / Graph: how to display the acquired data. The graphs are divided by parameter and can be
•
printed separately.