Menu 1 Basic settings loading bridges
Overcurrent hydraulic motor (menu item 10)
Depending on the set current value, the control switches off the
pump if this value is exceeded.
In order to set the correct current value for the overcurrent, you
have to determine the actual value first. For adjusting, proceed as
follows:
1.
Select menu 1 "Basic settings loading bridge" in the control
and go to menu item 10 "Overcurrent motor pump".
2.
Lift the loading bridge for as long until the overpressure
valve is triggered. This occurs when the highest position of
the loading bridge is reached.
3.
Press and hold the
ð
The display now indicates the achieved actual value.
This occurs when the highest position of the loading
bridge is reached.
4.
Set the overcurrent value in a way that the value exceeds
the determined actual value by 1.
Defect on control or hydraulic system caused
NOTICE
by incorrect parameter
Incorrect settings can result in damages to the
control or hydraulic system. Adjust the parameter
to the hydraulic system used.
Automatic time (menu item 13)
The automatic time determines for how long the loading bridge is
lifted after actuating the return button in order to lower it safely
into the resting position afterwards.
To set the time duration for the automatic time, select the desired
value in the menu.
Defect caused by incorrect setting of
NOTICE
automatic time
Incorrect settings can result in damages to the
control or hydraulic system. Adjust the parameter
to the hydraulic system used.
Wheel chock / Resting position sensor (menu item 15)
If a wheel chock is connected to J6, the chock has to be activated
in the control. With the function being switched on, the loading
bridge's lifting function will only be enabled if the wheel chock is
activated. If a resting position sensor is connected, the resting po-
sition of the control is initiated if the sensor is activated. All valves
will be switched off. Select one of the following values in the
menu:
•
Value 0 = without function (default setting)
•
Value 1 = with wheel chock sensor
•
Value 2 = resting position sensor
Select door open sensor (menu item 16)
Depending on the used door open securing function, the accord-
ing sensor has to be selected in the control. Select one of the fol-
lowing values in the menu:
•
Value 0 = mechanical limit switch
•
Value 1 = inductive proximity sensor (default setting)
Test run
When programming has been completed, carry out a test run by
executing all operating functions. If all operating functions can be
carried out correctly, the connected loading bridge is ready for op-
eration.
16 - EN
button for 5 seconds.
6
Program overview
Menu 1 Basic settings loading bridge
menu
Entry
item
10
Overcurrent hydraulic pump
0-3
4-5
6-8
9-12
13
Automatic time
0 - 3
4 - 6
7 - 9
15
Connection J6: Wheel chock / resting position
0
1
2
16
Door open sensor
0
1
- -
Menu 2 door sealing (optional)
Menu
Entry
item
20
Door sealing
0
1
- -
Menu 5 Various settings
Menu
Entry
item
50
Key switch function (J7)
0
1
2
3
4
5
52
001-256 Entry of control address
53
Door control module and inflatable door sealing.
0
1, 2, 3 For control profiles see door control module
54
Extended control
0
1, 2, 3 For control profiles see extended control
59
0
- -
HA MS 400V / 230V
Selection
0 = 0.0 A / 1 = 2.6 A / 2 = 3.2 A / 3 = 3.8 A
4 = 4.4 A (default setting) / 5 = 5.0 A
6 = 5.6 A / 7 = 6.2 A / 8 = 6.8 A
9 = 7.4 A / 10 = 8.0 A / 11 = 8.6 A / 12 = 9.2 A
0 = 3 s / 1 = 5 s (default setting) / 2 = 7 s /
3 = 9 s
4 = 11 s / 5 = 13 s / 6 = 15 s
7 = 20 s / 8 = 25 s / 9 = 30 s
without function (default setting)
with wheel chock
sensor resting position
mechanical limit switch
inductive proximity sensor (default setting)
Exit menu
Selection
Off (default setting)
Inflatable door sealing
Exit menu
Selection
no function (default setting)
Inhibit control panel
Inhibit external control elements
Inhibit control panel and external control ele-
ments
Activate control elements for 10 seconds
Activate control elements for 300 seconds
Off (default setting)
Off (default setting)
Do not change control variant!
Exit menu