If the unit experiences any issues, the advanced electronics can
help you understand what is needed. After diagnosing and
solving the system fault, clear and reset the fault code.
To Reset
1. Press the ON/STOP button
fault code.
2. If the fault code does not clear, remove and
reinstall battery.
Please refer to the use and care manual for more details.
Please scan the QR code on the handle or call our toll free
number 877-362-4271 for assistance with fault codes or to
locate your nearest authorized service center.
NO PROBLEM
A SYSTEM
FAULT
IS INDICATED
RED/YELLOW LIGHT
POSSIBLE FAULT
SEQUENCE
Engine will not
start:
(1.1)
Unit will not
"power on":
(2.1)
PRESSUREADY® FAULT CODES
 28 
to clear and reset the
Green light ON = System Ready to Start
When a system fault occurs, the yellow light illuminates ON while the red
Yellow light ON
light flashes in a sequence, then the yellow light turns OFF and the red light
will continue to flash in a different sequence.
See the chart to determine the System Fault. Count the sequence of the red
light flashes to determine the system fault. All light sequences will continue
Yellow light OFF
to repeat until the problem is corrected. After diagnosing and solving the
system fault, clear and reset the fault code.
Example: The yellow light illuminates ON and the red light flashing once,
= Red light
then the yellow light turns OFF and the red light flashes once, this indicates
FLASHING
"the engine will not start" system fault. This light sequences will continue to
repeat until the problem is corrected.
POSSIBLE SOLUTION
Place engine ON/OFF
switch in ON position
Connect garden hose
and turn water flow ON
Place the unit on a level
surface
Fill fuel tank
Fill engine oil
Attach spark plug wire
Air filter filled with oil.
Clean air filter element.
Refer to engine
instruction manual for
correct procedure.
Take to authorized
service center
READY
gREEN
ON
YELLOW
RED/YELLOW LIGHT
POSSIBLE FAULT
SEQUENCE
Engine
suddenly
stopped
running: (3.1)
Engine speed is
to high: (3.2)
Battery voltage
low: (4.1)
Battery fault:
(4.2)
ENgLish
WATER FLOW
FAULT
OFF
28
POSSIBLE SOLUTION
Empty fuel tank, need to
add fuel
Oil level low, need to
add oil
Take to authorized
service center
Charge battery
Replace the battery