If enabled, the WINDOW/DOOR OPEN function allows the appliance to detect an
abnormal amount of cold air in the room.
In this condition, when the appliance is in heating mode or in set temperature mode
(the function is cannot be activated in functioning as fan), if it detects an ambient
temperature reduction by a few degrees, the function activates.
To enable the function:
a. When the appliance is connected to the mains power and in heating mode, press
to enable the WINDOW/DOOR OPEN function.
The LED TEMP turns on on the display.
b. Press
Each time the appliance is electrically connected, the WINDOW/
DOOR OPEN function is deactivated.
If this function is disabled, the appliance works normally.
- - - - - - - - - - - - - - - - - - - - - - - -
Temperature detection starts 1 minute after the open window/door detection.
The appliance detects ambient temperature at 5 minutes intervals to check if the
window/door has been closed.
If, during the checks, the appliance detects:
•
a difference of ≤8°C compared to ambient temperature, it keeps heating and the
open window/door detection continues,
•
a difference of >8°C compared to ambient temperature, it stops heating and
switches to stand-by mode and the open window/door detection stops.
Note:
•
When the appliance stops heating, the alarm report and the fan keep functioning
for 30 seconds, then they switch to stand-by mode. Both the LED TEMP and the
writing
-
Press
-
After restart, the open window/door detection starts again in the same ways
previously described.
-
Press
perature and the LED °C turns on (appliance in stand-by).
EN - 24
9.9 - Window/Door open function
a second time to disable the function.
flash on the appliance display.
to restart the appliance before it turns off.
to turn the appliance off; the display resume showing ambient tem-