Technical Data - Imer Group DELTA V 60 Manual De Uso, Mantenimiento Y Recambios

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

GB

TECHNICAL DATA ......................................................... 1.

DESIGN STANDARDS ................................................... 2.
NOISE EMISSION LEVEL .............................................. 3.
TYPE OF WORK ............................................................ 4.
SAFETY MEASURES .................................................... 5.
INSTALLATION .............................................................. 6.
CARACTERISTICS ........................................................ 7.
BLADE INSTALLATION ................................................. 8.
Combined blades ............................................................ 8.1
Finishing blades .............................................................. 8.2
Roughing blades ............................................................. 8.3
USE ............................................................................... .... 9.
Blade tilting adjustment .................................................... 9.1
Drive ............................................................................... 9.2
Control ............................................................................ 9.3
Roughing ........................................................................ 9.4
Finishing ......................................................................... 9.5
MAINTENANCE ............................................................. 10.
Initial RPM adjustement and engine timing ....................... 10.1
General maintenance ...................................................... 10.2
TROUBLESHOOTING / CAUSE / REMEDY .................. 11.
WIRING DIAGRAM
SPARE PARTS
Dear customer, congratulations on your choice of purchase: the IMER
SMOOTHING MACHINE, the result of years of experience, is a very
reliable machine tool equipped with all the latest technical innovations.
WORKING IN SAFETY
In order to be able to work in complete safety, the following instructions must
be read carefully
- This OPERATING AND MAINTENANCE manual must be kept on site
by the person responsible for the site, e.g. the YARD FOREMAN, and
must always be available for consultation.
- The manual should be considered as being an integral part of the
machine, and must be kept for future reference (EN 12100/2) until the
machine itself is disposed of. If the manual becomes damaged or lost,
a replacement can be obtained from the saw manufacturer.
- The manual contains important information regarding the preparation of
the site, use of the machine, maintenance and spare parts ordering.
Nevertheless, the installer and operator must both have adequate
experience and knowledge of the machine.
- In order that the safety of the operator, safe working and long life of the
equipment can all be guaranteed, the instructions in this manual must be
followed together with safety standards and health and safety at work
laws currently in force (use of suitable footwear and clothing, use of
helmets, gloves and goggles, etc. in accordance with S.I. N°3073 of 30/
11/92).
- Any non-compliance with the requirements of this manual will be
considered as improper use of the equipment, consequently IMER
INTERNATIONAL will be exonerated from any damages caused to
persons or things resulting from said improper use.
Special attention must be given to warnings with this symbol:
ALWAYS MAKE SURE THAT SIGNS ARE LEGIBLE
It is strictly forbidden to carry out any form of modification to the structure
or working parts of the machine.
Use of the machine is unadvisable with temperatures below 0° C.
IMER INTERNATIONAL decline any responsibility in the case of non-
compliance with laws and standards governing the use of this equipment.
In particular: improper use, defective power supply, lack of maintenance,
unauthorized modifications, partial or total inobservance of instructions
contained in this manual.
1. TECHNICAL DATA
B la d e r p m
M a x . b la d e d ia m e t e r
N u m b e r o f b la d e
M o t o r r a t in g
N o m . v o lt a g e
N o m . c u r r e n t
M o t o r r p m
M o t o r s t a r t in g
M o v e m e n t
W e ig h t
W e ig h t f o r t r a n s p o r t
IMER INTERNATIONAL S.p.A.
CONTENTS
r p m
9 3
m m
6 0 0
N °
K w
0 . 6
V / H z
2 3 0 / 5 0
A
r p m
1 4 0 0
m a n u a l
m a n u a l
k g
5 0
k g
5 3
DELTA "V" 60
1
HANDLEBAR
2
ACCELERATOR/SHUTOFF LEVER
3
BLADE LIFTING HANDWHEEL
4
CONTROL PANEL
5
HANDLEBAR HEIGHT ADJUSTMENT LEVER
6
LIFTING BAR
7
MOTOR
8
REDUCTION GEAR
9
BLADE GUARD
10 BLADES
2. DESIGN STANDARDS
The IMER Smoothing machine has been designed and constructed
in accordance with the following standards: EN ISO12100/1 - 2;
3. NOISE EMISSION LEVEL
The IMER Smothing machine has a noise emission level of (A) 74 dB.
4. TYPE OF WORK
The machine is designed for smoothing floors and horizontal surfaces
made of concrete or similar materials. Only IMER specification blades
must be used. Products must not be smoothed which are made of
tacky or semi-liquid materials, or with stone inclusions or projecting
iron rod reinforcements and in any case, liable to vestigial projction
risk or grating of blades.
5. SAFETY MEASURES
- The IMER Smoothing machine has been designed to work on building
sites under normal daylight conditions and in workshops with natural or
artificial lighting of not less than 500 lux.
It must never be used in explosion risk areas or fires or in
underground excavations.
-Use ear protectors and safety shoes.
This symbol appearingon the label indicates that THE
MACHINE MUST NOT BE USED IF THE PROTECTIVE
COVERS ARE NOT MOUNTED OR EFFICIENT.
- Do not remove the guards.
- To keep the different warning signals readable.
- The IMER smoothing machine can only function if all the safety devices
with which it is equipped are in perfect operation.
4
- The machine will not operate if the mains connection is defective.
- On-site power connection lines must be installed such that they cannot
be damaged. Do not install the smoothing machine on top of the mains
connection.
6
- The power lines must be installed such that water cannot penetrate into
the connections. Only use connectors fitted with protection against water
spray (IP 55).
- Repairs to electrical plant must only be carried out by specialized
personnel. Do not operate the machine during maintenance or repair
operations.
6
Fig.1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

1193000

Tabla de contenido