Hansgrohe Rainfinity 250 3-jet 04864700 Instrucciones De Montaje página 49

Tabla de contenido

Publicidad

Troubleshooting - Mixing Valve
Symptom
Insufficient water
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
Spout temperature does not
correspond with temperature set
Temperature regulation not possible
Safety stop button on the handle not
operating
Valve stiff
Shower drips continuously
Troubleshooting - Showerhead
Symptom
Showerhead drips for an extended
time after use
Poor flow from showerhead
Showerhead "droops" - falls to
lowest position
Possible Cause
– Supply pressure too low
– Filters are dirty
– Screen washer between
handshower and hose dirty
– Check valves dirty or worn
– Handle has not been justified
– Hot water temperature too low
– Thermostatic mixer cartridge dirty
or worn
– Hot and cold supplies are
reversed
– Spring dirty or worn
– Button dirty or worn
– Select stop valve dirty or worn
– Select stop valve dirty or worn
Possible Cause
– Spray channels clogged
– Spray channels clogged
– Filters clogged
– Tension screws should be
tightened
Recommended Action
– Check water pressure.
– Clean filter in front of the mixer
and on the thermostatic cartridge.
See page 35
– Clean the screen washer
– Clean the check valves, replace if
necessary. See page 35
– Justify the thermostatic mixer
handle. See page 28
– Increase hot water temperature
– Replace the thermostatic mixer
cartridge
– Follow the optional installation
instructions. See page 44
– Clean spring and/or button,
replace if necessary
– Replace the stop valve cartridge
– Replace the stop valve cartridge
Recommended Action
– Clean the showerhead - see
page 38
– Clean the showerhead - see
page 38
– Clean the filters - see page 40
– Tighten the tension screws - see
page 42
49

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rainfinity 250 3-jet 04863700

Tabla de contenido