Maintenance and cleaning
All cleaning of all parts must be carried out with the Boiler completely
cold and unplugged to avoid burns and thermal shock. The boiler does not
need much maintenance if used with certified quality pellet. The need for
maintenance varies depending on the conditions of use (switching on and off
repeatedly) and depending on the performance required.
periodic monitoring of the boiler to check its condition.
The automatic cleaning system of the brazier guarantees its cleaning only with
the use of ENplus A1 certified pellets. If a different pellet is used, check the
effectiveness of the system by checking that the bottom is free of residues after
3 days of operation. If not, change the type of pellet.
Parts
Self-cleaning brazier
Check and, if necessary, clean the
ash compactor (if any)
Cleaning the interior heat exchanger
/ smoke fan compartment
Cleaning complete exchanger
Clean "T" to exhaust
Flue
Door gasket ash and compactor
Internal parts
Flue pipe
Circulation pump
Heat exchanger (if any)
Cochlea compactor
Hydraulic components
Electromechanical components
◊ by the user / • by the specialised qualified technical assistance
Check every 60 days
Cleaning the ash collection compartment
Clean and empty the ash tray being careful with hot ash. The ash must be completely cold for a vacuum
cleaner to be used to remove it. Only if the ash is completely cold, you can also use a canister vacuum
cleaner suitable for picking up particles of a certain size. Cleaning ash and combustion chamber including
the spark plug lead.
Cleaning of stainless steel and satin-finish surfaces
Normally these surfaces do not need to be treated, but if they do, avoid cleaning them with abrasive materials.
For surfaces in stainless and satin brushed steel we recommend cleaning with a paper towel or a clean dry
cloth moistened with a detergent based on non-ionic surfactants (<5%) A spray glass cleaner may be used.
Avoid contact with skin cleanser and eyes. In case this happens, sprinkle with
plenty of water and contact the nearest medial center.
Every 2-3
Everyday
days
Every
Every 15
Every 30
week
days
days
It is recommended
Every 60-
Every 1
90 days
year
◊
◊
•
•
•
•
•
•
•
•
•
•
•
•
33