Annual cleaning
TO BE DONE BY THE SPECIALISED TECHNICAL
ASSISTANCE CENTRE (ON COLD BOILER)
1 Disconnect the electrical power supply.
2
Remove the right side, open the front door and remove
the protective casing of the cleaning mechanism.
3 Remove the fixing screws of the upper cover.
4 Gently remove the insulation paying attention
not to damage it. Then, remove the fixing wings
and the relevant plates to have free access to
the smoke chamber.
36
5 Remove the 2 screws supporting the bracket
of the gearmotor and turn it slightly to loosen
the chain
2
3
6 Remove the nut as shown in the image, and
the screws closing the lower compartment.
4
5
5
6