The values givenarevalid for nominalvoltages [U]230/240
V-50/60 Hz - 110/120 V - 60Hz. For lower voltage and
models for specific countries, these values can vary.
Please observe the article number on the type plata of
your machine.The trade names of the individual machines
may vary.
NoiseNibration lnformation
Noise determined according to EN 62841-1.
The typical sound pressure level of appliance determined
with a filter A product are: Sound pressure level 88 dB(A);
sound power level 99 dB(A). Tolerance K=3 dB
Wear hearing protection!
Total vibration values (vector sum of three directions)
determined according to EN 62841-1: Sanding drywal
a
=4 m/s
, K= 1,5 m/s
.
h
2
2
The vibration emission level given in this information sheet
has been measured in accordance with a standardised
test given in EN 62841-1 and may be used to compare
one tool with another. lt may be used for a preliminary
assessment of exposure.
The declared vibration emission level represents the
main applications of the tool. However if the tool is used
for different applications,with different accessories or
poorly maintained, the vibration emission may differ.
This may significantly increase the exposure leveloverthe
totalworking period.
An estimation of the levelof exposure to vibration should
also take into account the times when the tool is switched
off or when it is running but not actually doing the job.
This
may significantly reduce theexposure level over the total
working period.
ldentify additional safety measures to protect the operator
from the effects of vibration such as: maintain the tool
and the accessories,keepthe hands warm, organisation of
work pattems.