OPERATING INSTRUCTIONS
Draining the Tank
To help prevent tank corrosion and keep moisture
out of the air used, the tank of the compressor
should be drained daily.
To drain:
• Verify that the compressor is turned off.
• Holding the handle, tilt the compressor toward the
drain valve so that it's set in a lower position.
• Open the drain valve by rotating it 1/4 turn
counterclockwise.
• Keep the compressor tilted until all moisture has
been removed.
• Drain moisture from tank into a suitable container.
NOTE: Condensate is a polluting material and should
be disposed of in compliance with local regulations.
• If drain valve is clogged, release all air pressure
by pulling the safety valve. Remove and clean
valve, then reinstall.
WARNING:
Unplug the air compressor and release all air from
the tank before servicing. Failure to depressurize
tank before attempting to remove valve may cause
serious personal injury.
• Close the drain valve by rotating it 1/4 turn
clockwise.
8
14
Open
Close
H