Technical Data En - Abicor Binzel MFS-V2 Instructivo De Servicio

Ocultar thumbs Ver también para MFS-V2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68
2 Product Description
2.3 Technical Data
Fig. 1
Fig. 2
Ambient temperature
Transport and storage
Relative humidity
Tab. 2
Weight
Supply voltage
Max. welding current at 100 % / 60 % duty cycle
Wire feed rate
Fitted with standard rolls
Drive
Hose assembly connection
Protection type
Coolant inlet pressure
Coolant connections
Gas inlet pressure
Gas connection
Air-blast
Tab. 3
Weight
Connection voltage
Tab. 4
EN - 4
567
504
188
508
E-Box dimensions
225
M8
M-Drive dimensions
Temperature
M-Drive
E-Box
440
6
Ø
10
Ø
400
300
- 10 °C to + 40 °C
- 10 °C to + 55 °C
up to 90 % at 20 °C
approx. 13 kg
24 VDC
500 A / 600 A
20 m/min
ø 1.2 mm (steel wire)
4-roll (ø 30 mm)
Central plug WZ-2
IP21
5 bar / 70 °C
Quick coupling NW5
5 bar
Gas connection G 3/8"
Gas connection G 1/4"
approx. 25 kg
230 V / 50 or 60 Hz
MFS-V2
239

Publicidad