SPECIFICATIONS PLATE
1
2
4
3
5
3
1.
NAME OF APPLIANCE
2.
APPLIANCE REFERENCE
3.
SERIAL NUMBER + DATE OF MANUFACTURE
4.
ELECTRICAL SPECIFICATIONS
5.
CHARACTERISTICS OF GAS APPLIANCE
6.
CERTIFICATION NUMBER
These details should be quoted when the technical service is called.
GENERAL DESCRIPTION OF THE EQUIPMENT
1. Chimney
2. Container
3. Water inlet tap
4. Spark generation button
5. Gas valve tap
6. Door
7. Gas Inlet
8. Adjustable leg
SAFETY DEVICES
The pasta cooker has a safety thermostat which disconnects the heating if the tub runs dry.
The limiter switch must be restored by a specialised technician, after removing the front panel and
pressing the red button on the safety thermostat.
The ignition pilot light has a thermocouple which disconnects the gas supply if the flame goes out.
ACCESSORIES SUPPLIED
The CP-G905 pasta cookers are supplied with three GN 1/3 baskets.
The CP-G910 pasta cookers are supplied with six GN 1/3 baskets.
6
3