Connecting the Plumbing

Use hot or cold water and either hard or softened water in the humidifier.
1. Shut off the water.
CAUTION
Chemical Hazard.
Can cause personal injury or equipment damage.
Do not use any line connected to an air conditioner.
Do not use gas line.
2. Install the water shut-off valve in the water sup-
ply line at the location selected per local code.
3. Use 1/4 in. (6 mm) copper or OD tubing and
connect the shut-off valve to the inlet side of the
solenoid valve on the humidifier.
a. Insert the tubing into the solenoid valve fit-
ting and support the valve while tightening
the compression nut.
b. Place the brass compression nut over the
tubing.
c. Install brass insert into end of tubing.
d. Slide the plastic compression ring over the
tubing. (Discard copper compression ring
provided with valve.)
NOTE: To prevent leaking, use plastic (Delrin) sleeve
rings with plastic tubing. Use copper sleeve
rings only with copper tubing.
NOTE: Do not over-tighten the compression nut.
Moderate tightness prevents leaking.
e. Secure tubing with clamps provided.
4. Connect a 1/2 in. (13 mm) drain tube to the
humidifier drain fitting and run to the floor drain
(see Fig. 7).
a. Slide the drain clamp over the tubing.
b. Push the tubing over the drain nipple on the
humidifier.
c. Tighten the clamp around the tubing using a
pliers/hand to secure the humidifier drain.
d. Fasten the drain tubing (can use duct tape)
along the route to prevent movement and
ensure downward slope for correct drainage.
NOTE: Cut tubing to correct length so the tubing ter-
minates at the drain.
BRASS COMPRESSION NUT
Fig. 6. Installing feed tubing.
Fig. 7. Installing the drain tubing.
7
HE360 HUMIDIFIER
PLASTIC
COMPRESSION
RING
BRASS INSERT
SOLENOID
VALVE
M20177A
69-2631ES—13
M39203