SAFETY RULES

1. CAUTION – RISK OF SHOCK – Disconnect Power at the main
circuit breaker panel or main fusebox before starting and during the
installation.
2. WARNING: All wiring must be in accordance with the National
Electrical Code "ANSI/NFPA 70" and local electrical codes.
Electrical installation should be performed by a qualified licensed
electrician.
3. WARNING: Not suitable for use with solid-state speed controls.
4. WARNING: To reduce the risk of fire, electric shock, or personal
injury, mount to outlet box marked "acceptable for fan support of
15.9 kg (35 lbs.) or less" and use mounting screws provided with the
outlet box. Most outlet boxes commonly used for the support of
light fixtures are not acceptable for fan support and may need to
be replaced. Due to the complexity of the installation of this fan, a
qualified licensed electrician is strongly recommended.
5. The outlet box and support structure must be securely mounted and
capable of reliably supporting a minimum of 15.9 kg (35 pounds). Use
only cULus Listed outlet boxes marked "Acceptable for Fan Support
of 15.9 kg (35 lbs) or less".
6. The fan must be mounted with a minimum of 2.1 m (7 feet) clearance
from the trailing edge of the blades to the floor.
7. WARNING: Do not operate reversing switch while fan blades are in
motion. Fan must be turned off and blades stopped before reversing
blade direction.
8. Avoid placing objects in the path of the blades.
9. WARNING: make sure the power is disconnected before cleaning
your fan.
10. To avoid personal injury or damage to the fan and other items, be
cautious when working around or cleaning the fan.
11. Do not use water or detergents when cleaning the fan or fan
blades. A dry dust cloth or lightly dampened cloth will be suitable
for most cleaning.
12. After making electrical connections, spliced conductors should
be turned upward and pushed carefully up into outlet box. The
wires should be spread apart with the grounded conductor and the
equipment-grounding conductor on one side of the outlet box and
the ungrounded conductor on the other side of the outlet box.
13. Electrical diagrams are reference only. Light kits that are not
packed with the fan must be cULus Listed and marked suitable for
use with the model fan you are installing. Switches must be cULus
General Use Switches. Refer to the Instructions packaged with the
light kits and switches for proper assembly.
14. All set screws must be checked, and retightened where necessary,
before installation.
WARNING: TO REDUCE THE RISK OF PERSONAL INJURY, DO
NOT BEND THE BLADE BRACKETS (ALSO REFERRED TO AS
FLANGES) DURING ASSEMBLY OR AFTER INSTALLATION.
DO NOT INSERT OBJECTS IN THE PATH OF THE BLADES.
N.W. 10 KGS (22 LBS) / G.W. 11 KGS (24.2 LBS) (42 in.)
N.W. 11.5 KGS (25.3 LBS) / G.W. 12.5 KGS (28 LBS) (52 in.)
N.W. 13 KGS (28.6 LBS) / G.W. 14 KGS (31 LBS) (60 in.)