EN
Troubleshooting
Malfunction
Incorrect flushes (too soon,
too late, unwanted)
Water is running continuously
into the ceramic pan.
The ceramic pan is not being
flushed out properly.
Flush cannot be actuated.
Flush cannot be actuated.
The LED in the sensor
window flashes when a user
is in the user detection range.
Flush cannot be actuated.
The LED in the sensor
window lights up when a user
is in the user detection range.
1)
The state of battery charge can be checked using a Geberit app.
14
Cause
Sensor window dirty or wet
Sensor window scratched
Software fault
Technical fault
Flush volumes set incorrectly ▶ Contact a skilled person.
Ceramic pan is blocked with
limescale
Power failure
1)
Battery capacity low
1)
Batteries flat
Rectification
▶ Clean or dry the actuator
plate.
▶ Contact a skilled person.
▶ Interrupt the power supply
(mains fuse) for
10 seconds.
▶ Contact a skilled person.
▶ Descale the ceramic pan.
▶ Check the power supply
(mains fuse).
▶ Replace the batteries.
▶ Replace the batteries.