Check the load-bearing capacity of the floor, referring to the weight of the product given in the paragraph "TECHNICAL DATA". If
the floor does not have a suitable load-bearing capacity, adequate countermeasures must be taken.

MINIMUM SAFETY DISTANCES

Install the product in compliance with the recommended safety distances
from heat sensitive or inflammable materials and not inflammable, from
load bearing and other walls and also from wooden elements, furniture,
etc.
The minimum distances are:
- 4" (10 cm) from the wall behind the stove;
- 6" (15 cm) from the side wall;
- 32" (80 cm) in the heat radiation area and from the the hot air fan
outlet.
In the case of flooring that is heat sensitive or inflammable the floor
must be protected with non-combustible insulating material, e.g. sheets
ofsteelplate,marble,tiles,etc.
The floor protection must extend:
- under the product;
- a minimum of 6"(152 mm) in front of unit and beyond each side of
the fuel loading and ash removal opening (4" / 10cm from the external
side of the coating).
Connection to the flue must respect minimum safety distances from
heat-sensitive structural components or inflammable materials (wood
paneling, beams or ceilings, etc) shown in figures.
The stove will become hot while in operation. Keep children
away from all stovesurfaces.
Direct contact with stove while operating may cause skin
burns.
Keep any combustible product such as wooden furniture,
curtains, carpets, combustible liquids, etc. well away from the
stove when it is lit (minimum distance 32" / 80 cm).
It is recommended that greater distances than those indicated
above be left all round the stove to make any
necessary work on the appliance easier.
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
Certain local code restrictions may apply.
Check with Local Officials first before installing.
Fig. 4
SEEVENT
MANUFACTURER'S
INSTRUCTIONS
6"
6
REAR WALL
MIN 4"
6"
4"
FLOOR PROTECTION
32"
HEAT RADIATION AREA