EAS ELECTRIC ECRTH2 Manual De Instrucciones página 121

Mando por cable
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

221(PLC: 40222) t_DI_max
222(PLC: 40223) t_DI_hightemp
223(PLC: 40224) t_interval_C
224(PLC: 40225) dT1SC
225(PLC: 40226) dTSC
226(PLC: 40227) T4cmax
227(PLC: 40228) T4cmin
228(PLC: 40229) t_interval_H
229(PLC: 40230) dT1SH
230(PLC: 40231) dTSH
231(PLC: 40232) T4hmax
232(PLC: 40233) T4hmin
233(PLC: 40234) T4_IBH_on
234(PLC: 40235) dT1_IBH_on
235(PLC: 40236) t_IBH_delay
237(PLC: 40238) T4_AHS_on
238(PLC: 40239) dT1_AHS_on
240(PLC: 40241) t_AHS_delay
Maximum disinfection duration, range: 90~300 min, default
setting: 210 min
Disinfection high temperature duration, range: 5~60 min, default
setting: 15 min
Time interval of compressor start-up in cooling mode; range: 5~5
min, default setting: 5 min
Default setting: 5°C, range: 2~10°C, setting interval: 1°C
Default setting: 2°C, range: 1~10°C, setting interval: 1°C
Default setting: 52°C, range: 35~52°C, setting interval: 1°C
Default setting: 10°C, range: -5~25°C, setting interval: 1°C
Time interval of compressor start-up in the heating mode; range:
5~5 min, default setting: 5 min
Default setting: 5°C, range: 2-20°C;
Default setting: 2°C, range: 1~10°C, setting interval: 1°C
Default setting: 25°C, range: 20~35°C, setting interval: 1°C
Default setting: -15°C, range: -25-30°C, Setting interval1°C
Ambient temperature for enabling the hydraulic module auxiliary
electric
heating IBH, range: -15~10°C; default setting: -5°C
Temperature return difference for enabling the hydraulic module
auxiliary, range: 2~10°C; default setting: 5°C
Delay time of enabling the hydraulic module auxiliary electric
heating IBH,range: 15~120 min; default setting: 30 min
The trigger ambient temperature for turning on AHS
range: -15~30°C;default setting: -5°C
The temperature difference between the heat pump ' s leaving
water set temperature (T1S) and the heat,range: 2~20°C;
default setting: 5°C
Delay time for enabling the external heater A HS, range: 5~120
min;
default setting: 30 min
56
V.1

Publicidad

Tabla de contenido
loading

Tabla de contenido