Unit
address
H8
47
Pressure sensor fault
H9
48
Zone 2 water flow temp. sensor(Tw2) fault
The plate heat exchanger water outlet temperature
HA
49
sensor(Tw_out) fault
Hb
50
3 times PP protection and Tw_out<7℃
Communication fault between master unit and slave
Hd
52
unit(in parallel)
Communication fault between main board of hydraulic
HE
53
module and Ta/room thermostat transfer PCB
HF
54
Inverter module board EE PROM fault
HH
55
H6 display 10 times in 120 minutes
Low pressure protection (Pe<0.6) occurred 3 times in 1
HP
57
hour in cooling mode
C7
65
High temp. protection of inverter module
bH
112
PED PCB fault
F1
116
DC bus low voltage protection
L0
134
DC compressor inverter module fault
DC bus low voltage protection(from inverter module
L1
135
mostly when compressor running)
L2
136
DC bus high voltage protection from DC driver
L4
138
MCE fault
L5
139
Zero speed protection
L7
141
Phase sequence fault
Compressor frequency variation greater than 15Hz within
L8
142
one second protection
Actual compressor frequency differs from target
L9
143
frequency by more than 15Hz protection
Content
60
Remarks
Sensor TW2
Sensor Tw_out