Filling Up The Internal Refrigerant Container - Waeco ASC 6300 G LE Instrucciones De Uso

Ocultar thumbs Ver también para ASC 6300 G LE:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

EN
1. In the basic menu use the cursor keys
Short selection
Free selection
Other selections
ENTER-OK
2. Press
ENTER
3. Use the cursor key
Refrigerant Test
Hybrid service
Service.
ENTER-OK STOP-EXIT
4. Press
ENTER
5. Enter the password
6. Use the cursor keys to activate any fields you need (dark fields are activated).
Oil bottle
150ml
UV bottle
150ml
7. Press
ENTER
8. Press
STOP
to access the standby menu..
12.11

Filling up the internal refrigerant container

When the A/C service unit is started for the first time, the A/C service unit displays Error 12, because the inter-
nal refrigerant vessel must be filled from an external refrigerant vessel with at least 2000 g of refrigerant.
1. Press
STOP
to confirm.
The current supply quantities are displayed in the standby menu.
2. Connect the external refrigerant vessel to the A/C service unit.
Note Observe the instructions on the refrigerant vessels. Vessels for the R1234yf refrigerant have a
left-hand thread.
There are three different types of refrigerant vessel available:
• Refrigerant vessels without rising pipe: These refrigerant vessels have one connection. When filling the A/
C service unit, the connection must be on the bottom (turn the vessel upside down).
• Refrigerant vessels with rising pipe: These refrigerant vessels have one connection. When filling the A/C
service unit, the connection must be at the top (place the vessel upright).
• Refrigerant vessels with rising pipe: These refrigerant vessels have two connections. To top up the A/C
service unit, use the connection marked with L (= liquid). When filling the A/C service unit, the connection
must be at the top (place the vessel upright).
16
to confirm.
to select Service.
to confirm.
.
2688
250ml
500ml
250ml
500ml
to confirm.
or
to select Other selections.
 

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Asc 6400 g leAsc 6300 gAsc 6400 g91033031079103303108