Primary filter cleaning with electric filter
shaker
According to the quantity of vacuumed material, if the vacuum
gauge pointer goes from the green zone to the red zone, shake
the primary filter by pressing the electric filter shaker button for
10 ÷ 15 seconds.
CAUTION!
Stop the machine before using the filter shaker.
Do not shake the filter with the machine functioning, as
this could damage the filter.
Wait before restarting the machine, to allow the dust to settle.
Replace the filter element if the vacuum gauge pointer stays
in the red zone even after the filter has been shaken (see
"Primary and absolute filters disassembly and replacement").
[ NOTE ]
If the indicator is still in the red area. The vacuum hose or
one of the accessories may be clogged, and not the filter.
Clean these parts if this is the case.
Primary
cartridge
automatic system
Figure 10
1.
Filter cleaning solenoid valve 1
2.
Filter cleaning solenoid valve 2
3.
Filter cleaning solenoid valve 3
4.
Filter cleaning solenoid valve 4
5.
Cartridge container pressure switch
When it is necessary to vacuum very fine dust continuously
without stopping to clean the filters, the Manufacturer provides
the machine of a multi-cartridge filtering system.
The unit is equipped with a fully automatic electropneumatic
device to alternately clean the filtering cartridges, which
guarantees continuous service.
Electric panel, powered with a 24V rating, is complete with
cyclic timer to regulate the following times:
T1 Filter cleaning time
Opening time of the solenoid valve for backwashed air exhaust
into the cartridge.
The shorter the time, the more energetic the cleaning action
will be.
T2 Work hold time
Time between one cartridge cleaning operation and the next.
T3 Time between cleaning cycles
Time between one cleaning cycle and the next.
Check the arrows on the knobs of the timer for the exact
regulation.
Replace the filter element if the vacuum gauge pointer stays
in the red zone even after the filter has been shaken (see
"Primary and absolute filters disassembly and replacement").
[ NOTE ]
If the indicator is still in the red area. The vacuum hose or
one of the accessories may be clogged, and not the filter.
Clean these parts if this is the case.
filter
cleaning
with

Emptying the container

Before proceeding with these operations, turn off the
machine and remove the plug from the power socket.
Check the machine filtration class.
Before emptying the container it is advisable to clean the filter
(see "Cleaning the primary filter" paragraph).
Release the dust container with lever, then remove and
empty it.
Clean the machine as described in the "Maintenance,
cleaning and decontamination" paragraph.
Wash the container with clean water if aggressive
substances have been vacuumed.
Make sure the gasket is in perfect condition and correctly
positioned.
Place the container back in position and secure it again.
After the cleaning session, leave the machine running for at
least 60 seconds before turning it off.
Avoid switching on/off too frequently.

Emptying of the liquid container

Before proceeding with these operations, turn off the
machine and remove the plug from the power socket.
Check the machine filtration class.
Before emptying the container it is advisable to clean the filter
(see "Cleaning the primary filter" paragraph).
Release the container with the lever and remove it, then
remove the liquid stop device and empty it.
Clean the machine as described in the "Maintenance,
cleaning and decontamination" paragraph.
Wash the container with clean water if aggressive
substances have been vacuumed.
Make sure the gasket is in perfect condition and correctly
positioned.
Place the container back in position and secure it again.
After the cleaning session, leave the machine running for at
least 60 seconds before turning it off.
Avoid switching on/off too frequently.
The filter element will be wet after liquids have been
vacuumed.
A wet filter element can quickly become clogged if the
machine is then used to vacuum dry substances.
For this reason, make sure that the filter element is dry or
replace it with another one before using the machine for dry
materials.
13
CTS22 - CTS40 - CTT40
CAUTION!
Figure 11
[ NOTE ]
CAUTION!
Figure 11
[ NOTE ]
[ NOTE ]