4.3
Heating Mode
WARNING: Before starting, ensure that the filtration pump is operating correctly.
Step 1: Press
to switch on your pump.
Step 2: Press
to switch from one mode to another until the heating mode is displayed.
Step 3: Using buttons
EXAMPLE:
If you have selected 28°C, your screen will display:
Required
"Blinking"
temperature
Useful information about how the heating mode operates
When the incoming water temperature is less than or equal to the required temperature (setpoint temper-
ature) -X°C, the heat pump will switch to heating mode. The compressor will stop when the temperature of
the incoming water is greater than or equal to the required temperature (setpoint temperature) +Y°C.
Indicators for adjustment range X and Y
X : adjustable parameter from 2° to 10°C, default setting is 3°C
Y : adjustable parameter from 0° to 6°C, default setting is 0°C
4. Use
select the required temperature (15-40°C).
and
Once the symbol
blinking, the required temperature
is validated and is replaced by the
water's current temperature (25°
in our example).
20
Current water
temperature
stops
Current temperature
of the ambient air