Maintenance Work; Repairs; Fault Tracing - Von Arx DTF 25 SH Instrucciones De Manejo

Ocultar thumbs Ver también para DTF 25 SH:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DTF 25 SH • Operating Manual

Maintenance work

Always interrupt the energy supply before performing maintenance work.
Wear
All tools and tool components are wear parts and will be worn out after a given period of use.
They must then be replaced. The service life of the individual components varies.Apart from
wear caused by operating use, it also depends on the type and characteristics of the material of
the surface to be treated and on the requisite power during use.
Changing wear parts
All Von Arx wear parts and replacement parts are made on the latest machines. This guarantees
a perfect fit for all parts.
Do not use spare parts of unknown manufacture! Even if they look the same, there may be
considerable differences in manufacture and/or materials which may be prejudicial to active
and passive safety.
All warranty claims lapse if spare parts other than those made by Von Arx or recommended
makes are used.
Changing the dust apron
Check the dust aprons regularly and replace them in good time.
Changing the drive belt
Always interrupt the energy supply before performing maintenance work.
Change toothed belt and v-belt
1. Loosen the screws from fan wheel guard and take them away
2. Loosen the screws from auxiliary belt guard and from belt guard and take them away
3. Loosen the screws from bent tensioning roller (not taking them away) and push the bent
tensioning roller to the right
4. Turn the spindle at the motor sleigh clockwise (relax of strap)
5. Loosen Taper-Lock from motor shaft and take away toothed belt
6. Change v-belt
Assembly in reversed order – test the tension in the belt with your thumb (the drive belt should
give a little, but not more than 10 mm).

REPAIRS

Von Arx machines are sufficiently robust to ensure that your appliance will probably far outlive
its drive motor. Arrange for your Von Arx Customer Service to fit a new motor.
Drive modes (e.g. LPG engine-electric motor) must not be changed!
Alterations to the electrical are prohibited!

FAULT TRACING

Electric motor fails to start:
1. Are all the plugs connected to the mains supply?
2. Is voltage present in the mains power supply?
3. Has the emergency STOP switch not been locked in its raised position? (check by turning the
red knob lightly)
4. Is the fatigue switch pawl correctly in position and secured?
If the engine still cannot be started, consult an authorized dealer for your engine brand or refer
to your nearest Von Arx Customer Service Agency.
LPG engine fails to start:
1. Is fuel available?
2. Is the fuel supply system OK?
3. Is there engine oil?
4. Are the filters clean?
Repairs
13

Publicidad

Tabla de contenido
loading

Tabla de contenido