Technical Information
Water pressure
Recommended
Maximum
Hot water temp.
Recommended
Maximum
Max. flow rate
Hole size in mounting surface
Max. depth of mounting surface
* Please know and follow all applicable local plumbing
codes when setting the temperature on the water heater.
Installation Considerations
• For best results, Hansgrohe recommends that
this unit be installed by a licensed, professional
plumber.
• Inspect this faucet thoroughly before installation.
Claims for shipping damage made after
installation will not be honored.
• Please read over these instructions thoroughly
before beginning installation. Make sure that
you have all tools and supplies needed to
complete the installation.
• Protection against backflow is provided by a
double check valve.
2
15 - 75 PSI (0.1 - 0.5 MPa)
145 PSI (1 MPa)
120°-140° F (48° - 60° C)*
158°F (70° C)*
1.75 GPM (6.6 L/min)
1⅜" (35 mm)
2⅜" (60 mm)
The hot and cold supply hoses included
with this faucet are for use with ⅜ stops.
If your stops are a different size, install
new stops. Adapters are not available
from Hansgrohe.
Do not rotate the spout further than 360°
or damage to the hose will result.
• Keep this booklet and the receipt (or other proof
of date and place of purchase) for this product in
a safe place. The receipt is required should it be
necessary to request warranty parts.