Error
91
Code
Probable Cause
- Accumulation of impurities in the hydraulic
system.
- The system can not raise the pressure to the
test pressure.
- Low pressure Rail.
- Bad contact on sensor or DRV valve.
- Damaged sensor.
- Damaged DRV.
- Problems of leak in the injector.
- Connections with sealing faults.
- Test DRV installed in high pressure
connections.
- Tank pump with flow problems caused by
damage to the fuse, dirt in the pump filter or
wear.
- High pressure pump with problems.
- Phase failure relay detecting failure on the
power line.
- Phase failure relay with problems.
- Contactor with problems.
- AC power board with problems.
- Bad contact at the motor activating terminals.
- Problems with activating the AC power driver.
Error
92
Code
Probable Cause
- Cancel the heating process by the user.
Error
163
Code
Probable Cause
- CPRC parameterizes SOM board with
frequencies greater than 80 Hz.
Error
164
Code
Probable Cause
- CPRC parameterizes SOM board with
timeout greater than 65 seconds.
TM 514 – COMMON RAIL TEST
Unable to reach test pressure during the TESTS process.
- Restart the machine and try the operation
again.
- Check the external high pressure connections.
- Check the presence of the DRV valve in the
high pressure connections of the tank (it should
not remain in case of sensor and injector
testing).
- Check the tank pump fuse.
- Check for accumulation of dirt in the tank
pump pre-filter.
- Check that the filter and fluid have been
replaced properly.
- Check that the tank pump can be heard by
turning on.
- Check that the three-phase motor can be
heard by turning on.
- Check that the fault relay and phase sequence
status LEDs are on (or consistent with the
label).
- Check that the power line is adequate.
- Contact Technical Assistance to perform the
complete periodic maintenance.
Stop the heating process.
- Restart the process and allow the automatic
heating of the fluid.
Parameterization error - frequency
- Contact the manufacturer.
Parameterization error - timeout
- Contact the manufacturer.
207
Functional error!
Solution
Functional error!
Solution
Solution