Error
197
Code
Probable Cause
- Injector in trouble.
- Occurrence of error 195/196.
Error
198
Code
Probable Cause
- Bad contact connector on the injector.
- Leak in CH1 drain valves.
- Loosen the conditioner screw.
- Float stuck/soaked.
- Incorrect LED voltage/supply current.
- Injector failure.
Error
199
Code
Probable Cause
- Bad contact connector on the injector.
- Leak in CH2 drain valves.
- Loosen the conditioner screw.
- Float stuck/soaked.
- Incorrect LED voltage/supply current.
- Injector failure.
Error
200
Code
Probable Cause
- Jet breaker adapter disconnected.
- Leak in drain valves.
- 3 way valves disconnected.
- 3 way valves with leaks.
Error
201
Code
Probable Cause
- Jet breaker adapter disconnected.
- Leak in drain valves.
- 3 way valves disconnected.
- 3 way valves with leaks.
Error
208
Code
Probable Cause
- Remote configuration parameters were not
written to the SOM board.
TM 514 – COMMON RAIL TEST
Return tightness test failed
- Check injector situation.
Low coefficient of determination CH1
- Check the condition of the electrical
connector.
- Check the jet breaker connection on the
inserted device.
- Contact the manufacturer.
Low coefficient of determination CH2
- Check the condition of the electrical
connector.
- Check the jet breaker connection on the
inserted device.
- Contact the manufacturer.
Timeout for dead volume fill SOM CH1
- Check the condition of the electrical
connector.
- Check the jet breaker connection on the
inserted device.
- Contact the manufacturer.
Timeout for dead volume fill SOM CH2
- Check the condition of the electrical
connector.
- Check the jet breaker connection on the
inserted device.
- Contact the manufacturer.
FLASH write error
- Contact the manufacturer.
211
Solution
Solution
Solution
Solution
Solution
Solution