Connection of the protective conductor (PE):
Sensitivity when switching (with regard to the ambient brightness):
Time setting (switching off delay):
Function test:
Ensure that the motion detector is not obscured. Ensure that the coverage area is not restricted by items such as
through large furniture. To set the detection range and the daylight test, turn the knobs to the positions shown. The
motion detector is activated after a warm-up phase of approx. 30s. If no further movement takes place in the
sensing area of the sensor, the sensor switches off.
Installation recommendation (Fig 1b):
Mounting hole:
Maximum thickness of mounting surface:
Mounting depth:
Technical Data:
Operating voltage:
Maximum power consumption:
When connecting a lamp with protective conductor contact, the
protective conductor must be bypassed from the supply line to the lamp
with the aid of an additional terminal in the in-wall socket
This setting control can be used to regulate the switch-on sensitivity of this unit
depending on the ambient brightness (between 3 and 2.000 LUX).
The duration of the operating time can be set continuously from approx. 10s to
30min. The timer is restarted if a movement from the sensor is detected before the
set time has elapsed.
Ø63-66mm
≤10mm
≥25mm
220 -240V AC 50Hz
Max. 1.200W
Max. 600W