BFT GIOTTO BT A ULTRA 36 Instrucciones De Uso Y De Instalacion página 32

Ocultar thumbs Ver también para GIOTTO BT A ULTRA 36:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 49
Logic
Denition
Conguration of
command input IC 1.
IC 1
61
Conguration of
command input IC 2.
IC 2
62
Conguration of
AUX 0 output.
AUX 0
20-21
Conguration of
AUX 3 output.
AUX 3
26-37
Fixed code
FIXED CODE
Protection
Setting the
protection level
level
Serial mode
(Identies how board
SERIAL ODE
is congured in a BFT
network connection).
Address
ADDRESS
32
GIOTTO BT A ULTRA 36
ENGLISH
Cross out
Default
setting
used
0
Input congured as Start E.
1
Input congured as Start I.
2
2
Input congured as Open.
 
3
Input congured as Close.
4
Input congured as Ped.
3
5
Input congured as Timer.
0
Output congured as 2nd Radio Channel.
1
Output congured as SCA (gate open light).
2
Output congured as Courtesy Light command.
3
Output congured as Zone Light command.
6
4
Output congured as Stair Light
5
Output congured as Alarm
6
Output congured as Flashing light
 
7
Output congured as Latch
8
Output congured as Magnetic lock
9
Output congured as Maintenance
10
Output congured as Flashing Light and Maintenance.
1
11
Not available
12
output congured as barrier status
13
Lights on bar - open green, moving red ashing, closed red steady.
14
Lights on bar - open green, moving red ashing, closed red ashing.
Receiver is congured for operation in rolling-code mode.
0
Fixed-Code Clones are not accepted.
0
 
Receiver is congured for operation in xed-code mode.
1
Fixed-Code Clones are accepted.
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been
memorized in standard mode via the radio menu.
- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters
0
by repeating the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be added to
the receiver's memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver's memory.
E - The board's parameters can be edited via the U-link network
A - You are prompted to enter the password to access the programming menus
1
The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
0
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
2
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions D - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
3
B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
4
D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board's parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: This high level of security stops unwanted clones from gaining access and also stops radio
interference, if any.
0
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
1
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other boards.
0
 
SLAVE opposite leaves in local network : the control unit is the slave in an opposite leaves network
2
with no smart module (g.L)
MASTER opposite leaves in local network: the control unit is the master in an opposite leaves network
3
with no smart module (g.L)
Identifies board address from 0 to 119 in a local BFT net wor k connec tion.
[ ___ ]
0
 
(see U-LINK OPTIONAL MODULES section)
Optional extras