Before Starting The Equipment - EINHELL GE-SC 36/35 Li Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 114
Switch the appliance off when it is not in use.
Wear protective gloves.
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Damage to hearing if no suitable ear protec-
tion is used.
2. Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.
Warning!
This equipment generates an electromag-
netic fi eld during operation. Under certain
circumstances this fi eld may actively or pas-
sively impede medical implants. To reduce
the risk of serious or fatal injuries, we recom-
mend persons with medical implants to con-
sult their doctor and the manufacturer of the
medical implant prior to using the equipment.

5. Before starting the equipment

Important!
This product is supplied without an aerator roller
and without a catch bag. This product is allowed
to be used only with original accessories. More in-
formation about how to order the optional acces-
sories is provided at the end of the instructions in
section "7.4 Ordering replacement parts".
Important!
The equipment is supplied without batteries and
without a charger is allowed to be used only with
the lithium-ion batteries of the Power X-Change
series!
The lithium-ion batteries of the Power X-Change
series are allowed to be charged only with the
Power-X charger.
Warning!
Always pull out the safety plug before performing
any adjusting, repair, maintenance or cleaning
work on the equipment.
Anl_GE_SC_36_35_Li_SPK13.indb 23
GB
The scarifi er is delivered unassembled. The com-
plete push bar must be assembled and mounted
before using the scarifi er.
Follow the operating instructions step-by-step
and use the pictures provided as a visual guide to
easily assemble the machine.
Fitting the push bar brackets
(see Figs. 5 and 6)
Remove the quick-release lever (Fig. 5/
Item 11) and the washer (Fig. 5/Item 12)
Connect the push bar bracket (Fig. 5/Item 5)
to the fastening screw. Make sure that the
curve in the tube (Fig. 6/Item A) is on the out-
side.
Now put the washer back on and tighten with
the quick-release lever.
The same tilt angle must be set for both push bar
brackets!
Fitting the lower push bar (see Fig. 7)
Slide the lower push bar (Fig. 7/Item 4) onto
the push bar brackets.
Now join the tubes together using the screws
(Fig. 7/Item 13), washers (Fig. 7/Item 12) and
quick-release levers (Fig. 7/Item 11) supplied.
Fitting the upper push bar
(see Fig. 8 to Fig. 10)
The upper push bar (Fig. 8/Item 3) has two
holes one beneath the other for further height
adjustment of the push bar.
Position the upper push bar (Fig. 8 / Item 3)
such that its holes line up with the holes of the
lower bar.
Now join the tubes together using the screws
(Fig. 8/Item 13), washers (Fig. 8/Item 12) and
quick-release levers (Fig. 8/Item 11) supplied.
Use the cable clips (Fig. 9/Item 10) to attach
the power cable to the tubes of the push bars
so that it is possible to open and shut the
ejector flap (Fig. 10/Item 10).
Please ensure that the ejector fl ap can be opened
and closed easily!
Fitting the optional catch basket
(see Figs. 11-14)
Push both frame parts into each other (Fig.
11).
Pull the grass basket over the metal frame
(Fig. 12).
Pull the rubber clips over the metal frame (Fig.
13).
To hang the grass basket on the scarifier you
- 23 -
08.03.2022 13:41:13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

34.206.80

Tabla de contenido