Bestway FLOWCLEAR 58678 Manual Del Propietário página 4

Ocultar thumbs Ver también para FLOWCLEAR 58678:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
Standby mode: At the end of the cycle, the display shows "00". At this time, the chlorinator will automatically enter the standby mode.
The day after, approximately at the same time, it will automatically run again. If you unplug the Chlorinator, connect the plug the next day, and press
the power button, the chlorinator will work according to the working hours set the previous day.
1. This table shows the recommended working hours for the normal maintenance of the chlorinator connected to the pool.
2. For cleaning the pool, please run it at 1.5-2 times the time shown in the table for the first use, and run it according to the normal
working hours once the chlorine level is reached.
3. On the first use or if the water in the pool is dirty, run the chlorinator until the level of chlorine is correct or the water is clean.
Refer to the working time shown in the table below.
Pool size
Gallon
Litre
1000
3785
7570
2000
11355
3000
15140
4000
18925
5000
6000
22710
7000
26495
It is recommended to cover the surface of the pool during the operation of the product to help increase the level of chlorine in the pool.
ATTACHING A BASE TO THE CHLORINATOR
Follow the below instructions. There must be two
holes with a diameter of 8 mm and a spacing of
165 mm on the base. The product can be fixed
on a cement base or a wooden platform. The
total weight of the base should not be less than
18 kg to protect the chlorinator from accidentally
falling over.
MAINTENANCE
ELECTROLYTIC CELL
To clean the electrolytic cell, follow the instruction in the section
to scale. In order to maintain the best results, we recommend opening and checking the electrodes every month. However, if the water quality of the
swimming pool is hard water (high content of calcium and magnesium ions), the electrodes may need to be cleaned manually on a regular basis.
To clean the electrolytic cell, it is suggested to use a solution of 50% water/50% vinegar, or check with your pool dealer the suitable chemical
product. Be sure to avoid chemical product that can damage the Titanium plate.
WATER CHEMICAL BALANCE
Available chlorine
Combined chlorine
pH value
Total alkalinity
The hardness of calcium
Stabilizer (cyanuric acid)
• If the concentration of chlorine exceed the recommended level, it can be dangerous to use the pool. Test the chemical balance before using the
pool. If using the test strip, check the expiration date, as the test result may be inaccurate if passed the expiration date.
BESTWAY
TEST STRIPS (INCLUDED IN THE PRODUCT)
®
The test strips can test the concentration of "free chlorine", "PH" and "total alkalinity" in the water at the same time. It is recommended to check the
level of the chemical in the water every day and before use.
• Immerse a whole strip of test paper in water and take it out immediately.
• Keep the test paper level and wait for 15 seconds. Do not shake off excess water.
• Please compare the "free chlorine", "PH" and "total alkalinity" grades of the test paper with the color plate attached to the bottle.
STORAGE
• Remove all accessories; be sure to clean and dry all before the storage. If all the parts are not completely dry, mold may result. We strongly
recommend to disassemble the Chlorinator when the environment temperature is below 10ºC / 50ºF.
• Store the Chlorinator in a dry place with a moderate temperature between 10ºC / 50ºF and 38ºC / 100ºF.
Recommended Pool Working Time Set Table
Working time (hours) under different ambient temperatures
10 - 19°C(50 - 66°F)
1
2
4
5
6
7
8
. Drawings are for illustration purposes only. May not reflect actual product. Not
Minimum
Best Value
0
0.5 - 3.0 ppm
0
7.2
7.4 - 7.6
40 ppm
80 - 100 ppm
50 ppm
100- 250 ppm
10 ppm
20 - 40 ppm
20 - 28°C(68 - 82°F)
1
3
4
6
7
8
9
Maximum
3.0 ppm
0
0.2 ppm
7.8
120 ppm
350 ppm
50 ppm
4
29 - 36°C(84 - 97°F)
1
3
5
7
8
9
10
2-M6 nut
2-M6 bolt
18KG