Descargar Imprimir esta página

SNOWJOE iON100V-21SB-CT Manual Del Operador página 19

Ocultar thumbs Ver también para iON100V-21SB-CT:

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting
m
WARNING!
Always turn the tool OFF and remove the battery pack(s) before performing any adjustments, maintenance,
or repairs to your cordless blower vac.
Problem
1. Batteries are flat.
Unit will not
start
2. Batteries are not locked in
position.
3. The safety button is not depressed
The auger doesn't
1. Auger belt is wore out
rotate while the
2. Auger belt is not assembled properly
motor is running
1. There's no power.
Chute doesn't
rotate when
2. Too much wet snow are accumulated
pressing the
around the chute and preventing the
button
chute rotating.
Snow left on
1. Worn out auger blades
the ground after
2. Worn out scraper bar
cleaning
Possible Cause
1. Charge the batteries
2. Reinsert the battery, and try to start the machine
again.
3. Depress the safety button, and pull the switch bar
lever.
1. Change the auger belt
2. Check the auger belt, make sure it's assembled
tightly on the rail
1. Make sure the battery pack(s) are charged and
locked in position.
2. Clean the wet snow around the chute.
1. Replace the blades
2. Replace the scraper bar
19
Solution

Publicidad